8
Installation and Servicing
SECTION 1 - GENERAL
Table 1 - General Data
Note.
Gas consumption is calculated using a
calorific value of 38.7 MJ/m
3
(1038 Btu/ft
3
) gross
or 34.9 MJ/m
3
(935 Btu/ft
3
) nett.
To obtain the gas consumption at a different
calorific value:
a.
For l/s
- divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
3
)
b. For Btu/h
- multiply the gross heat input (kW)
by 26.8
c.
For ft
3
/h
- divide the gross heat input (Btu/h)
by the gross C.V. of the gas (Btu/ft
3
)
d.
For m
3
/h
- multiply l/s by 36
Key to symbols
GB
= United Kingdom
IE
= Ireland
(Countries of destination)
PMS
= Maximum operating pressure of water
C
13
C
33
C
53
= A room sealed appliance designed for connection via ducts to a
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream of
the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
* The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
26
33
38
Gas supply
2H - G20 - 20mbar
Gas Supply Connection
15mm copper compression
Injector Size
mm
4.15
4.65
4.9
Inlet Connection
DHW
15mm copper compression
Outlet Connection
DHW
15mm copper compression
Flow Connection
Central Heating
22mm copper compression
Return Connection
Central Heating
22mm copper compression
Flue Terminal Diameter
mm
100
Average Flue Temp-Mass Flow Rate
(DHW)
30ºC 11g/s
32ºC 13g/s
35ºC 15g/s
Average Flue Temp-Mass Flow Rate
(CH)
63ºC 11g/s
68ºC 13g/s
73ºC 13g/s
Maximum Working Pressure (Sealed Systems)
bar
2.5
Maximum Domestic Hot Water Inlet Pressure
bar
10.0
Minimum Domestic Hot Water Inlet Pressure*
bar
1.1
1.6
1.9
Electrical Supply
230 V ~ 50 Hz.
Power Consumption
W
86
93
93
Fuse Rating
External : 3A Internal : T4A HRC L250 V
Water content
CH litre
1.2
DHW litre
1.0
Packaged Weight
kg
38.05
38.15
38.35
Maximum Installation Weight
kg
32.65
32.75
32.95
Boiler Casing Size
Height mm
826
Width mm
395
Depth mm
278
*Required for maximum flow rate. Boiler operates down to 2 l/min DHW delivery
** In areas of low water pressure the DHW restrictor can be removed
Maximum DHW Input :
26
33
38
Nett CV kW
24.3
30.4
35.4
Gross CV kW
27.0
33.7
39.3
Gas Consumption m
3
/h
2.51
3.14
3.66
(ft
3
/h)
(89)
(111)
(129)
Maximum DHW Output
kW
26.1
32.7
38.2
DHW Flow Rate at
35°C temp. rise
l/min
10.7
13.4
15.7
DHW Specific Rate
l/min
12.5
15.6
18.3
Table 2 - Performance Data - Central Heating
Table 3 - Performance Data - Domestic Hot Water
Boiler Input:
Max.
Min.
26
33
38
Boiler Input ‘Q’
Nett CV kW
24.3
4.9
6.1
7.1
Gross CV kW
27.0
5.4
6.7
7.9
Gas Consumption
m
3
/h
2.51
0.50
0.62
0.73
Boiler Output:
Non Condensing
kW
24.2
4.8
6.1
7.1
70ºC Mean Water Temp.
Condensing
kW
25.6
5.1
6.4
7.5
40ºC Mean Water Temp.
Seasonal Efficiency*
SEDBUK 2005 91.1%
91.1%
91.1%
SEDBUK 2009 89.6%
89.6%
89.6%
NOx Classification
CLASS 5
NOx Level (mg/kWh @ 0% 0
2
)
26.4
28.1
35.3