IMAX XTRA -
Users
2 CONTROL OF WATER TEMPERATURE AND SYSTEM TYPES
The water temperatures and system types are factory preset but may be adjusted. The following settings can be changed.
1. DHW Temperature (optional)
2. DHW System
3. CH System
4. Flow Temperature
P A R A
Press
Display
DHW Temperature (Optional)
o
C
Instant water heater
40
65
Storage Tank
20
70
60
Press
Display
Factory
Setting
Upper
Limit
Lower
Limit
Description
DHW System
00 = Off
01
01 = On
02 = Off + pump continuous
03 = On + pump continuous
1. 6 0
2. 0 1
CH System
00 = Off
01 = On
01
02 = Off + pump continuous
03 = On + pump continuous
3. 0 1
CH Flow Temperature
o
C
20 90 82
4. 8 2
Press the 'step' button until the desired parameter is displayed.
Press the '+' or '-' buttons to change the values.
The parameter setting can be stored by pressing and releasing the 'store' button, the new setting flashes twice to show it has been
accepted. The new setting will become active when the 'mode' button is pressed several times or if the display is left. If the display
is left, after 20 minutes it automatically returns to 'standby' mode.
Parameter settings and limits are listed below.
Parameter mode is entered from standby mode by pressing the 'mode' button once.