GENERAL INFORMATION
The PEO202P Ideal logic timer board allows numerous programmable functions in various combinations
(See Universal Commercial Logic Function Chart). This logic board contains an adjustable time for
automatic closing which is adjustable from 1 second to 4 minutes.
When the time function is selected (Switch #3 ON), the timing sequence starts when the gate activates the
open limit switch. (At this time the TIMER ACTIVE LIGHT comes ON.) The gate will automatically
close after a predetermined time. The timing range is adjustable from 1 second to 4 minutes. The timer is
reset by activating any input, which is selected to set the timer. Any combination of inputs will allow you
to have more switches ON than are shown for any one input. For example: Input #2 SAFETY (Stop and
Reverse) plus input #8 TIMER (Open and Always Set Timer). Switch #3 and switch #5 will both be ON.
GENERAL CIRCUIT BOARD CONNECTIONS
The numbers below refer to the terminal strip (#1 - #15) in the gate operator. All inputs are normally open.
SAFETY
Terminals 2 and 3 In the open position, this input will prevent the gate from closing, or if the timer is used,
hold the timer until the input is cleared. In the closing cycle, activation of this input with reverse the gate to
full open position, and if the timer is used, set and hold the timer until the input is cleared.
AUX TIMER
Terminals 2 and 4 this input is active only when timer circuit is used. In the open position, activation of
this input will hold the timer until the input is cleared. In the closing cycle, activation of this input will
reverse the gate to full open position, set the timer and hold the time until the input is cleared.
TIMER
Terminal 2 and 5 This input is active only when the timer circuit is used. When the gate is in the closed
position activation of this input will open the gate and set the time. In the open position, this input will
hold the timer until the input is cleared. In the closing cycle, activation of this input will reverse the gate to
full open position, set the timer and hold the timer until the input is cleared.
ELECTRICAL LOGIC TIMER BOARD GENERAL CAPABILITY
TIMER BOARD
Terminal 2 and 6 This input is active only when the timer circuit is used. Then the operator is in the full
open position, activation of this input will hold the timer until the input is cleared. This input will NOT
reverse the gate when the operator is in the closing cycle.
SINGLE BUTTON
Terminal 2 and 11 When in the closed position, activation of this input will open gate. When in the
opening cycle, activation of this input will stop the gate. If gate is stopped in mid travel, this input will
open the gate when activated. In the full open position, activation of this input will close the gate. In the
closing cycle, this input will reverse the gate to the full open position.
CLOSE
Terminal 2 and 12 When the gate is in the full open position or stopped in mid travel, activation of this
input will close the gate.
OPEN
Terminal 2 and 13 When the gate is in the full closed position or stopped in mid travel, activation of this
input will open the gate.
STOP
Terminal 7 and 8 This is a NORMALLY CLOSED circuit. Anytime the stop circuit is opened, all
functions of the logic board will cease. Then the circuit is once again closed, the desired input will have to
be reactivated to start the function once again.
4
Summary of Contents for HYJD-25
Page 7: ...IDEAL MANUFACTURING INC 3 ALTERNATE FENCE SCHEMES HYJD 25 HYJD 25E SSHYJD 25 SSHYJD 25E...
Page 11: ...AB AB ALLEN BRADLEY IDEAL MANUFACTURING INC...
Page 12: ...AB AB AB ALLEN BRADLEY IDEAL MANUFACTURING INC...
Page 13: ...9 AB AB ALLEN BRADLEY IDEAL MANUFACTURING INC...
Page 23: ...IDEAL MFG INC 19 ACTUATOR CYLINDER WITH COMPONENTS RGHY 3008...
Page 35: ......
Page 40: ...IDEAL MANUFACTURING INC 36...
Page 42: ...IDEAL MANUFACTURING INC 38 RGHY 3042 A TILT A WAY ROAD GATE LOOP DETECTOR DIAGRAM...
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......