Points for Boiler User

Note.

In line with our current warranty policy we would ask that you check through the following guide to identify any problems

external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance

we reserve the right to levy a charge for the visit, or for any pre---arranged visit where access is not gained by the engineer.

Troubleshooting --- Typical Non Product Faults

Problem

Solution

Boiler is not working for central heating

or hot water

F

Is there power to the boiler i.e. is the left hand side green LED (A) alight and

flashing every 4 seconds. If not this is not a boiler fault --- contact the installer

F

Check pressure gauge on boiler shows a minimum of 1 bar.

If not re---pressurise via the filling loop to 1 bar (if unsure contact your installer), turn

off the tap on the filling loop and press the reset button (D) to reset the boiler. If

unable to do so or if the pressure continues to drop after filling then contact your

installer

F

Is the lockout signal lamp (E) alight --- Press boiler reset button (D) --- If boiler still

does not fire contact the installer

Boiler goes through ignition sequence but
will not fire for either central heating or hot
water and then goes to ignition lockout

F

Check gas supply (try another gas appliance cooker/fire etc) If no gas supply

then this is not a boiler fault --- Contact the gas supplier

Fan & pump run continuosly but there isno

attempt at ignition

F

Check that air pressure switch test caps, on top of the boiler, are fitted correctly

Operating for hot water but will not operate

for central heating

F

Check that integral programmer is set to an “on” period and the function switch

is set to “auto”--- If it still does not operate contact your installer

F

If fitted with an external programmer check that the central heating channel is set

at an “on” period --- If it still does not operate contact your installer

F

Check the room thermostat is set at the required temperature --- Test the room

thermostat by turning fully up --- If this does not respond contact your installer

F

Check the radiator temperature control (C) is set at the winter setting for central

heating

The nature of all combination boilers is to heat up water directly from the incoming mains water supply directly through the boiler to

supply domestic hot water at the stated flow rates, (as shown in the boiler installation instructions), to achieve a 35° C temperature rise.

As the ambient temperature of the cold main varies during the summer and winter months it is likely in the colder winter months that

the flow rate will need to be reduced at the outlet taps to achieve the same temperatures achieved in the warmer summer months.

This is not a fault with the appliance but is relevant to the varying temperature of the incoming cold mains water supply.

europa Consumer Hepline:

Tel: 01482 498 660

The boiler manufacturer pursues a policy of continuing improvement in the

design and performance of its products. The right is therefore reserved to

vary specification without notice.

Manufactured for the seller; Aldwych House, 81 Aldwych, London,

WC2B 4HQ

Summary of Contents for Europa 224

Page 1: ......

Page 2: ...case must be allowed for servicing After installation the following clearances are allowable during use providing the encasing parts are removeable for servicing The bottom clearance can be reduced to 20mm 3 4 The front clearance can be reduced to 50mm 2 BOILER CONTROLS B C D E F G A A Appliance On lamp B Domestic hot water temperature control C Main switch and radiator temperature control D Boile...

Page 3: ... SHUT DOWN THE BOILER For short periods To turn the boiler off set the function selector C to the O position The appliance On lamp A will flash every 4 seconds For long periods When you do not expect to use the boiler for a long period 1 Switch the electricity supply off 2 Shut off the gas supply cock and the valves for the water circuits fitted under the boiler 3 If necessary empty the water circ...

Page 4: ... above for the ON setting and confirm by pressing the enter button D Proceed in the same way for other settings Setting example shown in Fig 3 A ON time 7 45 day Monday to Friday B OFF time 10 30 day Monday to Friday A B Fig 3 Activating the timed settings Set the mode selector switch B to the AUTO position shown in Fig 4 The current time and day appears in the display The ON OFF display A indicat...

Page 5: ...ssing the button E or F and the operation can be forced on or off by pressing the button G The time delay can be set within the following ranges 1 to 23 hours with steps of 1 hour 1 to 27 days with steps of 1 day The time delay setting is activated by moving the switch B to the AUTO position The ON OFF display A flashes indicating that the current state of operation has been forced To delete the t...

Page 6: ...ition F Check that air pressure switch test caps on top of the boiler are fitted correctly Operating for hot water but will not operate for central heating F Check that integral programmer is set to an on period and the function switch is set to auto If it still does not operate contact your installer F If fitted with an external programmer check that the central heating channel is set at an on pe...

Reviews: