DIGITAL PROGRAMMER

Operating instructions

The

europa

combi boilers are equipped with a digital

programmer which controls the c.h. operation.

A

B

C

D

F

G

H

J

I

E

Display and control panel

A

ON---OFF display

B

Mode selector switch

C

Reset button

D

Enter button

E I

ncrease “+” setting button

F

Decrease “---” setting button

G

On---off button

H

Day selection buttons

I

Day display

J

Time display

Setting the current time and weekday

Note: with a new unit or when the reset button C has been

pressed and the selector switch B is to the

position, the first

day indicator I on the left and the time display J are flashing.

Set the mode selector switch B to the

position and press

the buttons E or F until the current time appears in the display

J.

Press the day selection button corresponding to the current

day, considering that button 1=Monday, button 2=Tuesday

and so on.

The clock starts by moving the switch B to the AUTO position.

Setting example shown in Fig. 1:

Current time 16.30, day Thursday.

B

Fig. 1

Setting the switching time and day (or days)

20 memory locations are available, corresponding to 10

on---off sequences.

Set the mode selector switch B to the

C1

position. The

symbols shown in Fig. 2 appear in the display.

B

Fig. 2

Press the buttons E or F to set the desired ON time.
Press the buttons H to set the desired day or days of

operation.
Press the “enter” button D to confirm the setting and to

continue programming the OFF time.
Set the OFF time as explained above for the ON setting and

confirm by pressing the “enter” button D. Proceed in the

same way for other settings.
Setting example shown in Fig. 3:

A --- ON time 7.45, day Monday to Friday.

B --- OFF time 10.30, day Monday to Friday.

A

B

Fig. 3

Activating the timed settings

Set the mode selector switch B to the

AUTO

position shown

in Fig. 4.
The current time and day appears in the display. The

ON---OFF display A indicates the current state of operation

(according to the settings).

B

Fig. 4

Note: when the mode selector switch B is in the

AUTO

position and the boiler is switched off at the fused spur

isolation switch, the display A indicates only the OFF state.

The other indications are blanked.

Reading the timed settings

Set the mode selector switch B to the

C1

position. The

symbols shown in Fig. 2 appear in the display.
Press the “enter” button D. Each time the button is pressed

the display shows the details of the next setting.
The day display I gives a flashing indication of the active day

or group of days.

Changing or deleting the timed settings

Set the mode selector switch B to the

C1

position. The

symbols shown in Fig. 2 appear in the display.
Press the “enter” button D until the display shows the setting

to be modified or deleted.
The day display I gives a flashing indication of the active day

or group of days.
Press the button (or the buttons) H corresponding to the day

(or days) for which it is intended to apply the modification.

The corresponding day display stops flashing and a new

switching time can be set or deleted.
The time setting can be modified now by pressing button E or

F and the operation can be switched on or off by pressing the

button G.

Summary of Contents for Europa 224

Page 1: ......

Page 2: ...case must be allowed for servicing After installation the following clearances are allowable during use providing the encasing parts are removeable for servicing The bottom clearance can be reduced to 20mm 3 4 The front clearance can be reduced to 50mm 2 BOILER CONTROLS B C D E F G A A Appliance On lamp B Domestic hot water temperature control C Main switch and radiator temperature control D Boile...

Page 3: ... SHUT DOWN THE BOILER For short periods To turn the boiler off set the function selector C to the O position The appliance On lamp A will flash every 4 seconds For long periods When you do not expect to use the boiler for a long period 1 Switch the electricity supply off 2 Shut off the gas supply cock and the valves for the water circuits fitted under the boiler 3 If necessary empty the water circ...

Page 4: ... above for the ON setting and confirm by pressing the enter button D Proceed in the same way for other settings Setting example shown in Fig 3 A ON time 7 45 day Monday to Friday B OFF time 10 30 day Monday to Friday A B Fig 3 Activating the timed settings Set the mode selector switch B to the AUTO position shown in Fig 4 The current time and day appears in the display The ON OFF display A indicat...

Page 5: ...ssing the button E or F and the operation can be forced on or off by pressing the button G The time delay can be set within the following ranges 1 to 23 hours with steps of 1 hour 1 to 27 days with steps of 1 day The time delay setting is activated by moving the switch B to the AUTO position The ON OFF display A flashes indicating that the current state of operation has been forced To delete the t...

Page 6: ...ition F Check that air pressure switch test caps on top of the boiler are fitted correctly Operating for hot water but will not operate for central heating F Check that integral programmer is set to an on period and the function switch is set to auto If it still does not operate contact your installer F If fitted with an external programmer check that the central heating channel is set at an on pe...

Reviews: