37
insTallaTion
Solar Thermal -
Installation and Servicing
32 in roof mounTing (Ts 8001) - mounTing sysTem 45
o
elevaTion
ins
T
alla
T
ion
5. Cut off any excess length from the bench screw.
(Measurement D = max 45mm)
6. Attach the first mounting triangle as described in 6a-6c
6a. Screw the base bracket to the support bracket (A)
Order: screw – base bracket – support bracket - washer – nut
6b. Screw the base bracket to the attachment bracket on the front (B)
Order: screw – attachment bracket – base bracket – washer – nut
5
6
6a
6b
207786-2.indd 37