Operation

In normal operation the control unit display (F) will show the
codes:

O - Standby 

  (no demand for heat)

C - Heat demand being supplied.

During 

ignition

 the LED (E) will flash.

During 

normal running

 the LED will remain illuminated.

Note. 

If the boiler fails to light after 3 attempts the fault code 'L' 'F'

will be displayed.

Press and hold the reset button (D) for 2 seconds then release.
The boiler will repeat the ignition sequence.  If the boiler fails to
light consult a CORGI registered installer.

Control of water temperature

The boiler controls the central heating radiator temperature to a
maximum of 82

0

C, adjustable via the CH thermostat knob (C).

Approx CH flow temperatures for the boiler thermostat settings
are:

Knob Setting

Flow Temperature

0

C

0

F

Minimum

66

150

71

160

77

170

Maximum

82

180

To shut down the boiler

1. For short periods

Set the mains on/off switch (A) to OFF.

2. For longer periods

Set the mains on/off switch (A) to OFF.  Switch the electricity
supply to OFF.    For longer periods the entire system should be
drained, inlcuding the domestic hot water supply.

To relight the boiler

Repeat the procedure detailed in 'To light the boiler'.

Frost Protection

If no frost protection is provided and frost is likely during a short
absence from home leave the heating controls (if fitted) at a
reduced temperature setting.
For longer periods the entire system should be drained.
If the system includes a frost thermostat then,during cold
weather, the boiler should be turned OFF at the time switch (if
fitted) ONLY.  The mains supply should be left switched ON, with
the boiler thermostat left in the normal running position.

Boiler Overheat Thermostat

This thermostat will shut down the boiler in the event of
overheating.  Should this occur a fault code 'L' 'A' will be
displayed.  Press the reset button (D) and the boiler will relight.  If
the fault recurs turn off the boiler and consult a CORGI registered
installer.

CAUTION. 

 

To avoid the possibility of injury during the installation, servicing or cleaning of

this appliance care should be taken when handling edges of sheet steel components.

F

B

C

D

E

A

Ecl 1624

Legend

A

Boiler on/off switch

B

"Mains on" LED

C

CH thermostat knob

D

Reset button

E

LED

F

Display

1 BOILER CONTROLS