![IDEAL 61-603 Technical Manual Download Page 7](http://html1.mh-extra.com/html/ideal/61-603/61-603_technical-manual_3682259007.webp)
Page 5
Battery Replacement (refer to Figure 2)
1. Disconnect the test leads from any circuit under test and turn off meter.
2. Slide off the back case battery cover
3. Remove battery from compartment and unsnap the battery connector.
4. Install new 9V battery (NEDA #1604). An alkaline type is recommended.
5. Install new battery into compartment using care not to pinch or bind battery leads.
6. Slide battery cover along glide until cover snaps into bottom case.
Insure that cover aligned with snaps at bottom of the case.
Replacing Fuse (refer to Figure 3)
1. Disconnect the test leads and turn the range switch to “OFF”.
2. Remove the screw holding the bottom case cover, just above the battery cover.
3. The case bottom is secured to the case top by two internal snaps (at the LCD end).
lift up on the battery end until the case un-snaps.
4. Remove the defective fuse and replace with a 500mA, 250V Fast Acting fuse.
IDEAL #F-7 Type is recommended.
5. Replace bottom cover insuring that case is secured at the top by the internal snaps and
replace screw.
Form number TM61603
Rev 3 February 2002