background image

22

•A7216AA •A7221AA •A7227AA •A7697AA. 

The following procedures should be carried out after 

installation and every 12 months after to ensure that the valve is functioning correctly.

Check that:

1. The application of the thermostatic valve matches the approved designation.

2. The supply pressures are within the recommended range for the application.

3. The supply temperatures are within the permitted range for the application and comply with the 

    guidance for prevention of Legionella.

4. The mixed temperature is as required for the application.

Record:

5. Each hot and cold supply. (Make a note of the measuring device used).

6. The mixed water temperature at the outlet device.

Isolate:

7. The cold supply to the mixing valve and record the mixed water temperature after about 5 seconds.

 

The temperature should not exceed the value given in table (2) below.

•A7216AA •A7221AA •A7227AA •A7697AA. 

The purpose of servicing regularly is to monitor the 

performance of changes in system and valve set up. This may require the need to adjust either the sup

-

ply system or the valve.  The product should be checked and tested 12 months after commissioning. 

Firstly measure the water temperature at one of the outlets (bath fill or shower).

Carry out the cold water supply isolation test by isolating the cold water supply to the TMV, wait for 5 sec-

onds if water is still flowing check that the temperature is below 45°C.  If there is no significant change 

to the set outlet temperature (+/-2ºC or less change from the original settings) and the fail-safe shut off 

is functioning, then the valve is working correctly and no further service work is required. 

Notes:

A  residual  flow  is  permitted  during  the  commissioning  or  the  annual  verification  (cold  water  supply 

isolation test), then this is acceptable providing the water temperature is no more than 2ºC above the 

designated outlet temperature. 

Temperature readings should be taken at the normal flow rate after allowing for the system to stabilize. 

The sensing part of the thermometer probe must be fully submerged in the water that is to be tested. 

Any TMV that has been adjusted or serviced must be re-commissioned and retested in accordance with 

the instructions detailed above.

Note: 

 46°C is the maximum mixed water temperature from a bath tap.  The maximum temperature 

takes account of the allowable temperature tolerances inherent thermostatic mixing valves and tem-

perature loss in metal baths.  

It is not a safe bathing temperature for adults and children.

The British Burns Association recommends 37°C-37.5°C as a comfortable bathing temperature for Children.

In premises covered by the Care Standards Act 2000, the maximum mixed water temperature is 43°C

Table 2 A guide to maximum temperature sets

Application

Mixed water temperature

Permitted maximum temperature 

rise during site testing

Shower

41°C

43°C

10 

COMMISSIONING & PERIODIC CHECKS

11 

FREQUENCY OF REGULAR SERVICING

Summary of Contents for Ceratherm T50

Page 1: ...es A7225AA A7227AA bar shower mixer dual pack with overhead Rain shower Hand spray Thermostatic exposed two hole rim wall mounted bath shower mixers Ceratherm T50 INSTALLER After installation please p...

Page 2: ...XER A7224AA 17 7 4 QUICK GUIDE OF SHOWER PACK INSTALLATION A7225AA A7227AA 18 8 OPERATING PRODUCT 19 8 1 A7216AA A7221AA 19 8 2 A7225AA A7227AA 20 8 3 A7224AA A7697AA 20 9 TEMPERATURE ADJUSTMENT 21 10...

Page 3: ...for A7227AA A7225AA 1 2 Wrap over shower shelves 1 1 A7216AA A7221AA A7225AA A7227AA Wall mount mixers Shown A7216AA bar shower mixer supplied without shower kit Dimensions same for A7221AA bar showe...

Page 4: ...s assembled Basic bath shower mixer dimensions shown with wall mounting brackets assembled Dimensions are in millimetres may vary within permitted tolerances 1 3 A7224AA Deck mount mixer 1 4 A7697AA W...

Page 5: ...spray supplied only with these two product 5 Dimensions are in millimetres may vary within permitted tolerances 1 5 SHOWER PACKS Note The following three products do not include a shower pack kit A72...

Page 6: ...verts between hand spray overhead rain shower Includes dual shower pack shown below 600 Shower rail Handset pack supplied only with A7221AA Includes Idealrain Evo shower kit with three function handsp...

Page 7: ...lied in this kit for the bath shower mixer The G1 2 thread shown screws into nipples which have been pre fitted in the wall Shower valve shown without wall mounting brackets assembled Mixer supplied w...

Page 8: ...assembled Supplied only with A7224AA product Right side handle controls flow diverts between bath fill shower hand set Product is supplied without a shower kit 8 2 3 Deck mount mixer A7224AA DO NOT ap...

Page 9: ...ge tank which feeds the hot water system and the highest point on the shower spray plate When installing with a shower pump the use of a secondary tapping from the cylinder is highly recommended The p...

Page 10: ...gulator A pair of service valves for isolating both water supplies MUST be fitted below the bath to permit future maintenance of this product see sect 23 These should be fitted as close as practicable...

Page 11: ...tted zone of backflow risk for restrained hose which is longer than system design hose not permitted zone of backflow risk for unrestrained hose zone of backflow risk for restrained hose w c spill ove...

Page 12: ...water supply inlets of the mixer in an easily accessible location NOTE service valves are not supplied with thiese products see section 23 Shower Kit The flexible shower hose from the shower kit can...

Page 13: ...supply pipes should be run within the wall cavity Hot supply pipe should be on the left hand side and the cold on the right Ensure that the hot and cold pipes are positioned 150mm apart and are level...

Page 14: ...etrically opposed Drill carefully to avoid damaging conce aled pipework 4 5 3 2 Apply a smear of silicone sealant to the rear of the assembled brackets and push them over the pipework Screw both brack...

Page 15: ...kit 8 9 6 7 15 30 1 2 When the sealant has set fit the covers by screwing them onto the adaptors until they are flush with the wall The covers only need to be hand tight Screw the brass adaptors over...

Page 16: ...s To achieve a seal apply PTFE tape suitable for water to the G1 2 threads of the S connectors Screw the S Connectors into the nipples as shown Use a spanner on the square flats if necessary As shown...

Page 17: ...e tails of the legs into the two holes in the bath Align the legs and gently lower the mixer onto the rim of the bath IMPORTANT make sure the deck seals are still correctly located in the recesses of...

Page 18: ...7 4 Quick guide of shower pack installation A7225AA A7227AA 1 11 4 6 8 7 6 5 2 5 9 2 5 1 3 10 10 11 min 10 Nm min 700 18...

Page 19: ...about 50 of the maximum flow rate achievable through this product To obtain greater flow rate press hold the right button rotate this handle further downwards The handle will rotate a further 45 from...

Page 20: ...imum flow rate achievable through this product To obtain greater flow rate press hold the right button rotate this handle further downwards The handle will rotate further to the maximum flow stop Rota...

Page 21: ...efore sliding the handle off ensure the dot on the handle is inline with the 40 marker on the mixer 4 Slide the handle off the spindle 5 Slide off the plastic bush from the drive spindle 6 Turn on the...

Page 22: ...check that the temperature is below 45 C If there is no significant change to the set outlet temperature 2 C or less change from the original settings and the fail safe shut off is functioning then t...

Page 23: ...clean all filters ensure check valves are working and make sure all isolating valves are fully open Refit the shower handset to the flexible hose upon completion of the test NOTE In order to isolate t...

Page 24: ...se inline service valves if fitted 2 Fully open the flow or diverter handle to confirm water is switched off Unscrew the shower hose from the underside of the mixer This will permit some of the trappe...

Page 25: ...gely dependent upon the water quality and service life As a minimum we recommend removal both handles thermostatic cartridge flow control or diverter cartridge Cleaning the cartridge strainer screens...

Page 26: ...then use a sharp blade to lever the cap out taking care not to damage the chromed surfaces 2 Undo the handle retaining screw using a Phillips screw driver 3 Carefully slide the handle off from the car...

Page 27: ...idge with a new one Alternatively if the cartridge is functioning correctly clean it thoroughly reuse it 5 When fitting the cartridge into the bore ensure the lug on the cartidge is orientated into th...

Page 28: ...en Align the dot marker on the handle with the line marker on the stop sleeve Reverse the sequence to refit the handle 18 DIVERTER REPLACEMENT 1 Observe disassembling sequence as detailed in section 1...

Page 29: ...mixer bore screw the cartridge into the mixer body by hand then tighten with a spanner or socket Ideally torque to 16Nm min to 18Nm max 6 Refit the stop ring as illustrated above Align the marked arro...

Page 30: ...strainers from inside the mixer s inlet bores keep them in a safe location On a regular basis the anti splash nozzle on the bath mixer should be inspected and cleaned if necessary In areas where lime...

Page 31: ...A 861 373 NU 1 pcs 4 Cartridge G1 2 180 cpl A 861 245 NU 1 Set 5 Nipple G1 2 outside cpl A 861 374 NU 1 Set 6 Non return valve A 861 372 NU 1 Set 7 Escutcheon B 960 242 AA 1 pcs 8 Shower bracket conne...

Page 32: ...c Cartridge cpl A 861 371 NU 1 pcs 3 Stop valve with diverter A 861 375 NU 1 Set 4 Thread ring stopring cpl A 861 376 NU 1 Set 5 Connection nipple cpl A 861 387 NU 1 Set 6 Non return valve A 861 372 N...

Page 33: ...42 AA 1 Set 9 Connection nipple cpl A 861 385 NU 1 Set 10 Shower hose 1750 mm BE 175 AA 1 pcs 11 Handspray 110 3F 8l min B 2231 AA 1 pcs 12 Shower bar 1100 mm A 861 377 AA 1 pcs 12 Shower bar 1000 mm...

Page 34: ...Stop valve with diverter A 861 375 NU 1 Set 4 Thread ring stopring cpl A 861 376 NU 1 Set 5 Connection nipple cpl A 861 387 NU 1 Set 6 Non return valve A 861 372 NU 1 Set 7 Nipple G1 2 outside cpl A...

Page 35: ...ct MUST be fitted to permit future maintenance of the cartridges They also facilitate the cold water isolation test These should be fitted as close as is practicable to the water supply inlets of the...

Page 36: ...provements in design performance of its products This right is there fore reserved to vary specification without notice Partial or total reproduction or copying of this manual without our permission i...

Reviews: