- 7 -
GB
Sample programming of
MENU 4.2 SELF-CLOSING
In this case, a shower sensor is being programmed. You want the shower to switch
off automatically after
30 seconds
. You want it to flush automatically for
15 seconds
every
48 hours
.
Point the programming device with the infrared emitting diode at the sensor
(see direction of arrow on the housing).
Press
ON
to switch on the programming device.
The display reads VERSION x.x.x. Press to confirm.
Press or to select MENU 4 PARAMETER and press to confirm.
The display reads SENSOR VERSION 2008. Press to confirm.
The display reads MENU 4.1 HAND-WASH.
Press or to select the desired menu
MENU 4.2 METERING and press to confirm.
The display reads COMF.Timeout DURATION: 15 s.
Press or to confirm the desired time.
Select "
30 seconds
", press to confirm display: COMF.Timeout DURATION: 30 s.
The display reads Auto. RINSE FREQUENCY: OFF. Press or to select the
desired frequency "
48 hours
" with which the automatic flush is repeated. Press to
confirm display: Auto RINSE FREQUENCY: 48h.
The display reads Auto. FLUSH TIME:15s. Press or to select the desired flush
time for the automatic rinse "
15 seconds
".
Press to confirm the display: Auto.RINSE DURATION:15 s.
The display reads TRANSMISSION **** OK followed by BACKUP FUNCTION
Once you have set parameters, you can use the BACKUP FUNCTION to transfer
them one after the other to several sensors by pressing the button.
Once you have made all your settings, the programming device switches off auto-
matically after around 2 minutes.
TRANSMISSION ERROR
The display reads TRANSMISSION ERROR if an error occurs during transmission.
If this happens, check the power supply to the sensor and, if necessary, connect it to
the power.
Check the direction in which the infrared emitting diode is pointed and, if necessary,
adjust it.
Press to confirm TRANSMISSION ERROR.
The display reads BACKUP FUNCTION. Press to confirm. The set parameters
will be retransmitted.
The display reads TRANSMISSION **** OK followed by BACKUP FUNCTION
Once you have made all your settings, the programming device switches off auto-
matically after around 2 minutes.