- 6 -
GB
MENU 4 PARAMETER:
For programming the functions:
MENU 4.1 WASHBASIN
Automatic flush frequency and flush time for
washbasins.
MENU 4.2 SELF-CLOSING
Time delay, automatic flush frequency and flush
time, for example in showers.
MENU 4.3 ON/OFF
Time delay, automatic flush frequency and
flush time for units that switch on by proximity to
the sensor and switch off again by proximity to the
sensor. For example, hospital units.
MENU 4.4 URINAL
Flush, automatic flush frequency, flush time for
urinals.
MENU 4.5 PRE
Flush, automatic flush frequency, flush time for
urinals with pre-flush. The setting for pre-flush
cannot
be
changed.
MENU 4.6 TOILET
Flush, automatic flush frequency, flush time for
toilets.
MENU 4.7 KITCHEN
Default settings cannot be changed.
MENU 5 LANGUAGE
Press to confirm menu.
Press the arrow buttons to select the desired
language and press to confirm.
Explanation of functions:
Automatic flush frequency:
Frequency with which you want the unit to flush automatically. If it is programmed to
48h
, the unit flushes automatically every 48 hours.
Flush time:
Duration of automatic flush. If it is programmed to
15 s
, the unit is flushed automati-
cally for 15 seconds within the programmed frequency.
Time delay:
Time delay after flushing is activated by proximity to the sensor. If it is programmed to
15 s
, the flush ends automatically after 15 seconds.
Flush
(urinal)
Duration of flush after activation by moving away from the sensor. If it is programmed
to
8 s
, the flush lasts 8 seconds.
A manual for programming the sensing distance is included with all
electronic units. You do not need the programming device for this.