![IDEAL INDUSTRIES UniPRO MGig1 User Manual Download Page 21](http://html.mh-extra.com/html/ideal-industries/unipro-mgig1/unipro-mgig1_user-manual_617145021.webp)
UniPRO
152810
User Guide
Page 21
Modes of Operation
MGig1 has two modes of operation, Endpoint and Through Mode. To change between Endpoint and
Through Mode, from the home screen select PORTS (F2), choose the mode from the dropdown menu
and select APPLY (F3). Each time you change modes the detected services are PoE (802.3af/at. Not
Cisco pre-standard), ISDN S, PBX and Unknown. The IPv4 and IPv6 addresses assigned to the tester
(when available) are shown on the ‘Endpoint’ screen.
Endpoint mode
Endpoint is the mode from where all transmission tests and tools are run (Fig 20A).
Before a transmission test is run, a far end loopback must be set. Configuration of a SEL1 handset that
has been discovered as a target can be set remotely from the MGig1, see
page 29
A
B
Fig 20
Through mode
Fig 21
Through mode is for viewing statistics. Select
PORTS and choose Through Mode from the
dropdown menu and select APPLY (F3). MGig1
will detect the connected services and show them
on the display (Fig 21). It will attempt to negotiate
the highest connection rate between the two
networks.
Select STATS to view current traffic as graphs and
tables. Traffic is categorized as Top Users, Top
VLANs, MAC and LINK data. For further
Statistics on page 54.
For further information on Jobs see
Jobs on
page 56.
Summary of Contents for UniPRO MGig1