![IDEAL INDUSTRIES SignalTEK II User Manual Download Page 39](http://html.mh-extra.com/html/ideal-industries/signaltek-ii/signaltek-ii_user-manual_617117039.webp)
SignalTEK II
156810 Iss 1
User Guide
Page 39
Cable Tests
Wiremap
Setup
Cable Type
–
Cat3 UTP
- Cat3 STP
- Cat5 UTP
- Cat5 STP
- Cat5e UTP
- Cat5e STP
- Cat6 UTP
- Cat6 STP
- Cat7
- USOC
- ETH S1236
- ETH S1278
- ETH U1236
- ETH U1278
- IND. M12
- COAX RG59
Color Scheme
- None
- 568A
- 568B
- USOC
- TERA
Crossover Allowed
- Yes
- No
NVP
- Fixed 72%
- Custom 59% - 89%
Termination Types supported
and identified by icon
Active Remote -
#1 - #12
Remote Unit
Single-ended Wiremap
Tests
Faults
- Open circuit by pin
- Short circuit by pin
Length of pair
- Meters / Feet (Set in System Setup)
- Range 100m / 390ft
Double-ended WiremapTests
I/D
- Active Remote # / Remote icon
Indications
on Active Remote
- Voltage Warning (>±10v on any pins)
- Pass/Fail
Indications on Remote Unit
- See below
Faults
- Open circuit by pin
- Short circuit by pin
- Crossed pairs
- Split pairs
- Bridged shorts
- Remote shorts
Length of pair
- Meters / Feet (Set in System Setup)
- Range 100m / 390ft
Delay Skew
- Per pair (ns)
(continued)
www.vemco.pl