General
Individually adjustable values
• Temperature:
Indicated value +/- 50 °C respec/- 90 °F
Maximum value 650 °C respectively 1200 °F
At the program FREE SETTING, the entire range of
80°C – 650°C respectively 180°F - 1200°F is available
• Air volume: 7.0 to 17.5 cfm in 5 steps
Memory Function
Each individual adjustment can be confirmed with and is memorized. Without this
confirmation, the adjustment will be memorized automatically after 10 seconds of
operation.
Increase of the life expectancy
At the end of every use and before switching off, the hot air tool should be cooled down
to approx. 100°C / 210°F (COOL DOWN DEVICE).
Operating unit
Before operation
• Fit the adapter as required.
• If using an extension cord, it must be at least 14 gauge.
• The supply voltage must be as indicated on the nameplate.
• Supply cable and plug must be in perfect condition. No damage of any kind is acceptable.
OPERATION
5
°C/°F indication:
The temperature can be
adjusted in steps of
5°C/10°F with the
keys or
Air volume
The air volume can be
adjusted in 5 steps with
the keys or
minimum air volume
maximum air volume
USA
• Function program
• SET/CURRENT
temperature
• SET Air volume
• Operating elements
MENU