background image

30-603 Tool

IDEAL INDUSTRIES, INC

Becker Place, Sycamore, IL  60178  USA

815-895-5181  •  800-435-0705 in USA

www.idealindustries.com

International Offices:

Australia • Brazil • Canada • China • Germany • Mexico • UK

 

 

      1/11

©2011 IDEAL INDUSTRIES, INC

30-603 Adjustment Instructions for IDEAL BNC Connectors

START:  Identify your version of the Adjustable 30-603 IDEAL compression tool:

Current

 

version has a 

shorter plunger 

head 

and tool has adjustment lines

Previous

 version has a 

longer plunger head

 and tool has no adjustment lines

To Adjust Current Version:

Loosen the locknut/

plunger combo with a 

flat head screwdriver. 

Screw the plunger into 

the body of the tool as 

far as it can go. The 

locknut should be near 

the head of the plunger. 

Test a BNC connector for proper fit 

and compression.  Adjust plunger 

again for best fit if necessary. 

Loosen and remove the lock-

nut/plunger combo from the tool 

with a flat head screwdriver.  

Remove the locknut 

from the 

plunger.

Screw the plunger back 

into the body of the tool 

as far as it can go. 

 Do not 

use the locknut for BNC’s.

Test a BNC connector for proper fit 

and compression.  Adjust plunger 

again for best fit if necessary. 

To Adjust Previous Version:

*The 30-603 tool is recommended for occasional BNC users.  For installers who regularly use BNC and F connectors, 

the 30-793 tool is recommended as the above adjustments are not required to terminate BNC connectors.

Locknut

Plunger

Adjustment

Lines

The locknut is NOT required for proper operation of the 

30-603.  However, it is recommended for keeping the 

selected plunger setting locked in place.

 - or -