Systemiser SE - 

User's

To light the boiler

1.

Check that the electricity supply to the boiler is OFF.

2.

Open the controls access door .

3.

Set the on/off switch (C) and CH switch (D) to OFF.

4.

Switch ON the electricity supply to the boiler and check that all
external controls, e.g. programmer, room thermostat, etc., are
ON.

If a programmer is fitted, refer to the separate instructions
provided.

5.

Set the on/off switch (C) to ON and CH switch (D) to the desired
position.

The boiler will first execute a self-check cycle then commence
the ignition sequence.

Note. 

In the normal running STANDBY mode, the left hand

display digit indicates the boiler sequence and the other 2 digits
the boiler flow temperature.

Sequence

Boiler Status

0

Standby - no heat request

1

Purge

2

Ignition

3

Burner on - CH

6.

Close the controls door.

Operation

WINTER CONDITIONS - i.e. CH

Set the CH switch (D) to ON.

The boiler will fire and supply heat to the radiators.

SUMMER CONDITIONS

Set the CH switch (D) to OFF.

Control of water temperature

The boiler controls the central heating radiator temperature to a
maximum of 82 

o

C

To return the boiler to normal running STANDBY mode press the
RESET button.

To shut down the boiler

1. For short periods

Set the CH switch (D) to OFF.

2. For longer periods

Set the on/off switch (C) and CH switch (D) to OFF, and switch
the electricity supply to OFF.

Frost protection

This is provided automatically by the boiler control unit.  If  frost is
likely during an absence from home, turn the boiler off at the time
switches ONLY, leaving the mains supply switched ON.

If the boiler flow temperature falls below 7 

o

C the pump will run,

without the boiler firing, until the temperature exceeds 10 

o

C.

If the flow temperature falls below 3 

o

C the boiler will fire until the

temperature exceeds 10 

o

C.

Fault condition

If the boiler will not light initially or if a fault develops during normal
operation, the first digit and the last 2 digits of the display will flash
alternately. In this event press the RESET button and the boiler
will recommence the ignition cycle.

If the fault condition persists, turn the boiler OFF and consult your
CORGI registered installer.

Loss of system water pressure

The gauge (E) on the control panel indicates the central heating
system pressure.  If the pressure is seen to fall below the original
installation pressure of 1-2 bar over a period of time then a water
leak is indicated. In this event consult your local registered installer.

DO NOT OPERATE THE BOILER IF THE PRESSURE HAS
REDUCED TO ZERO FROM THE ORIGINAL SETTING.

Escape of gas

Should a gas leak be suspected contact your local gas supplier
IMMEDIATELY.

Do NOT search for gas leaks with a naked flame.

Condensate drain

The condensate drain must NOT be modified or blocked.

Blockage caused by debris or freezing can cause automatic
shutdown of the boiler.

If freezing is suspected and the pipe run is accessible, an attempt
may be made to free the obstruction by pouring hot water over the
exposed pipe and clearing any blockage from the end of the pipe.
If this fails to remedy the problem seek advice from your local
registered installer.

Cleaning

For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth and
finish off with a dry cloth.
DO NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a
registered installer, local gas authority or registered service
organisation.

THE LOG BOOK SHOULD BE COMPLETED AFTER

EACH SERVICE AND KEPT WITH THESE

INSTRUCTIONS

Summary of Contents for systemiser SE

Page 1: ...Supplied By www heating spares co Tel 0161 620 6677 ...

Page 2: ... and electrical connections before the boiler is fitted and it fits inside a cupboard Its compact size makes the Systemiser SE ideal for any kitchen It can be installed inside a cupboard without any ventilation Systemiser SE The system boiler you can rely on The Systemiser SE has been designed and developed with reliability as the number one priority But even the finest engineered product may deve...

Page 3: ... Natural Gas Models Only G C Appliance No 41 349 70 Gastec Certified P I No 0063 AS 3355 Destination Countries GB IE CAUTION To avoid the possibility of injury during the installation servicing or cleaning of this appliance care should be taken when handling edges of sheet steel components ...

Page 4: ...a registered installer Legend A Control door B Control panel C On off switch D Central heating on off switch E Central heating pressure gauge Introduction The Systemiser SE is a wall mounted room sealed super efficient condensing system boiler featuring full sequence automatic spark ignition and fan assisted combustion Due to the very high efficiency of the boiler condensate is produced from the f...

Page 5: ...until the temperature exceeds 10 o C If the flow temperature falls below 3 o C the boiler will fire until the temperature exceeds 10 o C Fault condition If the boiler will not light initially or if a fault develops during normal operation the first digit and the last 2 digits of the display will flash alternately In this event press the RESET button and the boiler will recommence the ignition cycl...

Page 6: ...HU5 4JN Telephone 01482 492 251 Fax 01482 448 858 Registration No London 322 137 Registered Office National Avenue Kingston upon Hull HU5 4JN A subsidiary of Caradon p l c The code of practice for the installation commissioning servicing of central heating systems Caradon Plumbing Limited is a member of the Benchmark initiative and fully supports the aims of the programme Benchmark has been introd...

Page 7: ...ers and our service We will be giving away a free boiler for the five best ideas every year to be selected by our Technical Director Please complete this form using extra sheets if required and post it or fax it to us on 01482 498699 Boiler details Model Size e g Classic RS 230 Mexico CF 60 etc Details on control panel door Date of Installation Installer details Name Address Post Code Telephone Pl...

Page 8: ...s and installer s introduction to the Ideal domestic boiler range The Ideal Householders Guide to assist the installer when presenting to his her customers Technical manuals required The Ideal C class combi boiler The Ideal Classic wall hung boiler The Ideal Classic System wall hung boiler The Ideal Classic LX Deluxe wall hung boiler The Ideal Mexico floor standing boiler The Ideal Minimiser heat ...

Reviews: