27
Mexico Super RS440 - RS470 -
Installation & Servicing
SERVICING
42 CONTROL PANEL REPLACEMENT
1.
Refer to Frame 37.
2.
Remove the 2 screws and lift off the
lower front panel. Refer to Frame 31.
3.
Pull off the thermostat knob.
4.
Disconnect the in-line electrical
connector between the control box
and PCB box.
5.
Unscrew the 2 screws and pull
down the control panel so that
the 2 tabs clear the top panel.
6.
Remove the thermostat phial
from the pocket. Refer to Frame
31.
7.
Remove the bottom screw and
remove the cover from the
control box.
8.
Remove the top screw and ease
the control box off the control
panel.
9.
Disconnect the mains electrical
supply from the terminal strip and
release from its clamp.
10.
Assemble new control box and
panel and fit to the casing in reverse
order.
11.
Insert control thermostat phial into
pocket and secure with the split pin.
Thermostat
bracket
Control
thermostat
Mex 2184
9
8
3
5
7
Clamp
43 OVERHEAT THERMOSTAT REPLACEMENT (if fitted)
1.
Refer to Frame 37.
2.
Remove the 2 screws and lift off the
lower front panel. Refer to Frame 31.
3.
Slacken the screw at the thermostat
pocket and withdraw the phial from the
pocket.
4.
Remove the thermostat retaining nut and
withdraw the thermostat from the control
panel.
5.
Transfer the electrical leads from the old
thermostat to the replacement (polarity is
not important).
6.
Fit the new thermostat, ensuring that the
alignment peg on the thermostat sits in
the small hole adjacent to the main fixing
hole, and reassemble in reverse order.
7.
Replace the lower front panel and
secure with the 2 fixing screws.
8.
Check the operation of the boiler.
"
mex2209
12.
Refit the in-line electrical connector between the control box
and the PCB box.
13.
Remove control box cover and remake electrical supply
connections to the terminal strip.
SER
VICING
200941-1.p65