Installation
GENERAL
1 BOILER WATER CONNECTIONS
2 FLOOR MOUNTING AND BOILER CLEARANCES
1.
This appliance is NOT suitable for use in a direct hot
water system.
2.
If the boiler is to be used on a sealed system, an
Overheat Thermostat Kit
is available and must be
installed in accordance with the instructions supplied
with the kit.
Boiler
Dim. A
CF3/40
152 (6")
CF3/50 - 3/80
226 (8 7/8")
Flammable materials must not be placed in close proximity to the appliance.
Materials giving off flammable vapours must not be stored in the same room as the appliance.
FLOOR MOUNTING
1.
The floor must be flat, level and
of suitable load bearing
capacity.
2.
The back of the boiler may be
fitted up to the wall.
BOILER CLEARANCES
The minimum overall dimensions of the space in which the
boiler is to operate and to facilitate servicing are as follows:-
Boiler Clearances
Top
One side
Aggregate
Total
'A' or 'B'
'A' + 'B'
Width C
CF3/40
20 (
3/4"
)
10 (
3/8"
)
50 (2
"
)
490 (19
1/4"
)
CF3/50,60,70
20 (
3/4"
)
10 (
3/8"
)
110 (4
1/2"
)
550 (21
5/8"
)
CF3/80
20 (
3/4"
)
55 (2
1/4"
)
110 (4
1/2"
)
550 (21
5/8"
)
Additional space will be required for installation, depending upon site
conditions.
IMPORTANT.
In order to facilitate gas
connection, a clearance of at least 100
mm (4") must be available at either the
LH side or the RH side DURING
installation. Refer to Frame 7.
A MINIMUM clearance of 25mm (1")
MUST also be maintained between the
flue pipe and any adjacent combustible
material.
In addition a MINIMUM clearance of
533 mm (21") MUST be available at
the front of the boiler, for servicing.