5 Boiler Resets in 15 minutes

Negative Differential 

Flow/Return Thermistor

1. Turn electrical supply to boiler off and on.
2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively 

a Gas Safe Registered Engineer if outside of the warranty period.  In IE contact a 

Registered Gas Installer (RGII).

If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively 

a Gas Safe Registered Engineer if outside of the warranty period.  In IE contact a 

Registered Gas Installer (RGII).

False Flame Lockout

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 

warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 

period.  In IE contact a Registered Gas Installer (RGII).

DISPLAY CODE ON BOILER

DESCRIPTION

Low Water Pressure

ACTION

Check system water pressure is between 1 & 1.5bar on the system pressure gauge.  To 

re-pressurise the system see Section 3.  If the boiler still fails to operate then please contact 

Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the 

warranty period.  In IE contact a Registered Gas Installer (RGII).

Check system water pressure is between 1 & 1.5bar on the system pressure gauge.  

To re-pressurise the system see Section 3.  If the boiler fails to operate then please contact 

Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the 

warranty period.  In IE contact a Registered Gas Installer (RGII).

8.  FAULT CODES

Flow Temperature Overheat 

or No Water Flow 

Flow/Return Differential > 

50°C

If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively 

a Gas Safe Registered Engineer if outside of the warranty period.  In IE contact a 

Registered Gas Installer (RGII).

Rotate all knobs fully clockwise, turn boiler power off and on then press restart.

Diverter Valve in mid-position 

for service

Flame Loss

Ignition Lockout

1. Check other gas appliances in the house are working to confirm a supply is present in 

the property.

2. If other appliances do not work or there are no other appliances, check the gas supply 

is on at the meter and/or pre payment meter has credit.  If the boiler fails to operate then 

please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer 

if outside of the warranty period.  In IE contact a Registered Gas Installer (RGII).

1. Check condensate Pipe for blockages (refer to Section 4)

2. Check other gas appliances in the house are working to confirm a supply is present in 

the property.

3. If other appliances do not work or there are no other appliances, check the gas supply 

is on at the meter and/or pre payment meter has credit.  If the boiler fails to operate then 

please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer 

if outside of the warranty period.  In IE contact a Registered Gas Installer (RGII).

Fan Fault

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 

warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 

period.  In IE contact a Registered Gas Installer (RGII).

Flow Thermistor

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 

warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 

period.  In IE contact a Registered Gas Installer (RGII).

Return Thermistor

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 

warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 

period.  In IE contact a Registered Gas Installer (RGII).

Outside Sensor Failure

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 

warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 

period.  In IE contact a Registered Gas Installer (RGII).

Low Mains Voltage

Contact a qualified electrician or your electricity provider.

Unconfigured PCB

Unconfigured/faulty PCB or gas valve short circuit.  Please contact Ideal (if under 

warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 

period.  In IE contact a Registered Gas Installer (RGII).

F 1

F 5

F 9

L 1

L 2

L 6

L C

F A

F U

     U

L 5

L 9

F 2

F 3

F 6

F 7

F 4

L 4

Summary of Contents for LOGIC COMBI C24IE

Page 1: ...uire Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers For the very latest copy of literature for specification and maintenance practices visit our website...

Page 2: ...les for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler ELECTRICITY SUPPLY This appliance must be ea...

Page 3: ...frost protection see Frost Protection PREHEAT DOMESTIC HOT WATER The domestic hot water heat exchanger within the boiler can be kept preheated to provide faster delivery of hot water at the tap This i...

Page 4: ...rds the MAX position to meet heating requirements This will depend on the house and radiators used Reducing the room thermostat setting by 1 C can reduce gas consumption by up to 10 WEATHER COMPENSATI...

Page 5: ...when using warm water as this may freeze and cause other localised hazards 4 Once the blockage is removed and the condensate can flow freely restart the appliance Refer to To Start the boiler 5 If th...

Page 6: ...e time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO HOT WA...

Page 7: ...heating mode The boiler is operating in domestic hot water preheat mode The boiler is operating in domestic hot water mode The boiler is operating in frost protection 7 NORMAL OPERATION DISPLAY CODES...

Page 8: ...ent in the property 2 If other appliances do not work or there are no other appliances check the gas supply is on at the meter and or pre payment meter has credit If the boiler fails to operate then p...

Reviews: