Installation and Servicing
SECTION 1 - GENERAL
24 30 35
Gas supply
2H - G20 - 20mbar
Gas Supply Connection
15mm copper compression
Injector Size
(mm)
4.15
4.65
4.9
Inlet Connection
Domestic Hot Water
15mm copper tail
Outlet Connection
Domestic Hot Water
15mm copper compression
Flow Connection
Central Heating
22mm copper compression
Return Connection
Central Heating
22mm copper compression
Flue Terminal Diameter
mm (in)
100 (4)
Average Flue Temp-Mass Flow Rate
(DHW)
63
o
C - 11g/s
68
o
C - 13g/s
73
o
C - 15g/s
CO
2
Content (± 0.7)
Max. DHW
9.5%
9.3%
9.5%
Min. CH
8.8%
8.8%
8.9%
Maximum Working Pressure (Sealed Systems)
bar (lb/in
2
)
2.5 (36.3)
Maximum Domestic Hot Water Inlet Pressure
bar (lb/in
2
) (kPa)
10.0 (145) (1000)
Minimum Domestic Hot Water Inlet Pressure* bar (lb/in
2
) (kPa)
0.8 (11.6) (80)
1.3 (18.9) (130)
1.3 (18.9)** (130)
Electrical Supply
230 V ~ 50 Hz.
Power Consumption
W
94
101
114
Fuse Rating
External : 3A Internal : T4A HRC L250 V
Water content
Central Heating
litre (gal)
1.2 (0.26)
Domestic Hot Water litre (gal)
0.5 (0.11)
Packaged Weight
kg
33.7
33.8
33.9
Maximum Installation Weight
kg
28.9
29
29.1
Boiler Casing Size
Height
mm
700
Boiler Casing Size
Height
mm
700
Width
mm 395
Depth
mm 278
Table 1 - General Data
Note.
Gas consumption is calculated using a calorific value of
38.7 MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different calorific value:
a.
For l/s
- divide the gross heat input (kW) by the gross C.V.
of the gas (MJ/m
3
)
b. For Btu/h
- multiply the gross heat input (kW) by 26.8
c.
For ft
3
/h
- divide the gross heat input (Btu/h) by the gross
C.V. of the gas (Btu/ft
3
)
d.
For m
3
/h
- multiply l/s by 3.6
Key to symbols
GB
= United Kingdom
IE
= Ireland (Countries of destination)
PMS
= Maximum operating pressure of water
C
13
C
33
C
53
= A room sealed appliance designed for connection via
ducts to a horizontal or vertical terminal, which admits
fresh air to the burner and discharges the products of
combustion to the outside through orifices which, in
this case, are concentric. The fan is up stream of the
combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group
H only.
* The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
*Required for maximum flow rate. Boiler operates down to 2 l/min DHW delivery
** In areas of low water pressure the DHW restrictor can be removed
Maximum DHW Input :
24
30
35
Nett CV
kW
24.3
30.4
35.4
Gross CV
kW
27.0
33.7
39.3
Gas Consumption
m
3
/h 2.512 3.135
3.657
(ft
3
/h) (89)
(111)
(129)
Maximum
kW
24.2
30.3
35.3
DHW Flow Rate
l/min
9.9
12.4
14.5
at 35°C temp. rise.
(gpm)
(2.2)
(2.8)
(3.2)
DHW Specific Rate
l/min
11.5
14.5
16.9
(gpm) (2.5)
(3.2)
(3.7)
Boiler Input :
Max.
Min.
24 30 35
Boiler Input ‘Q’
Nett CV
kW 24.3
4.9
6.1
7.1
Gross
CV kW
27.0 5.4 6.7 7.9
Gas Consumption
m
3
/h 2.512 0.500 0.627 0.734
(ft
3
/h) (89) (17.8) (22) (25.9)
Boiler Output :
Non
Condensing kW
24.2 4.8 6.1 7.1
Condensing
kW
25.6 5.1 6.4 7.5
Seasonal efficiency* SEDBUK 2005
91.1% 91.1% 91.1%
Seasonal efficiency* SEDBUK 2009
89.6% 89.6% 89.6%
NOx Classification
CLASS 6
Table 2 - Performance Data - Central Heating
Table 3 - Performance Data - Domestic Hot Water
Summary of Contents for INDEPENDENT+ COMBI 24
Page 4: ...4 Installation and Servicing...
Page 6: ...6 Installation and Servicing...
Page 63: ...63 Installation and Servicing...
Page 64: ......
Page 70: ...70 NOTES Installation and Servicing...