36
classic m -
Installation & Servicing
SERVICING
57 BOILER SEALING PANEL SEAL REPLACEMENT
Refer Frame 36.
1.
Remove the 2 retaining screws from the underside of the appliance.
Unhook and remove the front panel.
2.
Undo the 4 screws to remove the panel.
3.
Remove the old seal from the casing and thoroughly clean the casing
surfaces.
4.
Fit the new adhesive seals, note that they are supplied to the correct
length for the relevant sides.
5.
Reassemble in reverse order.
Note.
Ensure that the boiler sealing panel is correctly seated, compressing the
seal to make an airtight joint.
6.
Check operation of boiler. Refer Frame 36.
Ecl 1648
1
Ecl 1649
2
Ecl 1650
Seals
58 COLLECTOR HOOD REMOVAL
Refer to Frame 36.
1.
Remove the 2 spring clips securing
the collector hood to the heat
exchanger.
2.
Slide the flue spigot upwards into
the flue turret to allow the collector
hood to slide forwards.
3.
Remove the collector hood.
4.
Reassemble in reverse order
ensuring the location tabs in the
collector hood gasket fit into the
inter panel locations.
5.
Slide the flue spigot down from the
flue turret and locate on the
collector hood.
6.
Fit the spring retaining clips.
7.
Check operation of the boiler.
8.
Refer to Frame 36.
SER
VICING
Summary of Contents for Classic m3050