51
Installation and Servicing
SECTION 3 - SERVICING
3.27 CH WATER PRESSURE SWITCH REPLACEMENT
3.28 DHW FILTER & DHW FLOW REGULATOR CLEANING/REPLACEMENT
1. Refer to Section 3.8.
2. Drain the boiler. Refer to Section
3.19.
3. Pull off the two electrical
connections.
4. Using a suitable tool, pull out the
metal retaining clip.
5. Carefully withdraw the pressure
switch.
6. Fit the new pressure switch and
re-assemble in reverse order.
7. Refill the boiler.
8. Check operation of the boiler.
Refer to Sections 2.24 & 2.25.
1. Refer to Section 3.8.
2. Drain the boiler. Refer to Section 3.19.
3. Turn the housing anti clockwise and pull
forward to remove the cartridge.
4. Using a pair of pliers, pull out the plastic
filter/flow regulator.
5. Clean or replace filter as necessary.
6. Reassemble in reverse order.
7. Refill the boiler.
8. Check operation of the boiler. Refer to
Sections 2.24 & 2.25.
SER