background image

8

9

10

Note: iScan is used to scan barcodes. By default, iScan is 
installed and scanning is enabled upon delivery of the device. 
You can down the latest version from the following address:

http://t.cn/8k5hWCo

To start the iScan program and enable 

scanning, do as follows:

Enabling the Scan Function

1. Click the iScan icon on the menu page.
2. Click the blue slider on the right of Enable Barcode Scanning to 
enable the scanning function (if you click the slider again, the 
scanning function is disabled). 
3. Press the yellow key to scan a barcode. When the scanning 
indicator becomes blue from red and a beep is heard, the barcode
 is scanned successfully.

iScan

iScan

Back

Barcode scanning

To enable the NFC function, do as follows:

Enabling the NFC Function

1. Click the Settings icon on the menu page.
2. Select WIRELESS & NETWORKS/More > NFC. 
3. Click the blue slider on the right to enable NFC (if you click the 
blue slider again, NFC is disabled).
4. Put an NFC card close to the back of the iData 50. After a beep 
is heard, the card is read successfully.

NFC

NFC induction area

Network and Connection

Battery Safety Instructions

Battery

The battery of the iData 50 is a polymer battery. The battery and 
the battery cover are integrated.

Please use the charger specified by iData. Do not replace the 
desktop stand or adapter at random.

When you first get the battery, the remaining battery volume may 
be around 50%. You may charge the iData 50 by using the power 
adapter delivered with the iData 50 or a desktop stand (to be 
purchased separately). Charge the iData 50 for more than eight 
hours for the first time.

Do not contact battery electrodes by using metal objects, for 
example, keys, or short circuit the battery electrodes.

Do not put the battery in an environment that is too hot, too damp 
or corrosive. Do not squeeze or collide the battery.

Do not store the battery on a long-term basis when the battery is  
empty or is full. Store the battery when the battery volume is 
around 50%.

If you will not use the iData 50 for a long time, please take out the 
battery from the iData 50.

If the battery swells or expands, please replace the battery in time.

1. Fault: The iData 50 cannot be powered on.

Solution: Charge the iData 50.

2. Fault: After the iData 50 is connected to the charger, the charging 

identifier is not displayed.
Solution: Charge the iData 50 continuously for one hour. If the
charging identifier is still not displayed, contact iData after-sales 
service personnel. 

3. Fault: Charging is slow.

Solution: Make sure you use the original accessory for charging.

4. Fault: After a SIM card is inserted, the iData 50 cannot access the 

Internet.
Solution: Make sure that the SIM card is not in arrears and that the 
SIM card is correctly inserted.

Troubleshooting

After-sales Service

iData series product warranty card

Dear customer,

Thank you for choosing iData product. You may enjoy the following

services after buying iData product:

【Warranty of free repair service】

1)12-month warranty is given to the device and battery and 

3-month warranty is given to other accessories from the day 

of purchase against functional failure that is not caused due to 

manmade damage.

2)Our after-sale service department will mail out the repaired 

device within 24 hours after the device with any problem is 

received, so as to keep you wait for the shortest possible time. 

3)A device of the same model will be provided free of charge for 

replacement of the device that cannot be used normally after 

being returned for repair due to the same problem for 3 times 

in 1 year.

The parts needed for the product repair service will be available for 

no more than 1 year after the product manufacturing ceases.

Note:

Reminder:

Please contact our customer service staff before sending any  product 

to us. 

【Warranty of paid repair service】

You may choose to use our paid repair service under the following 

circumstances (including but not limited to):

1)There is no warranty card, or the valid invoice is missing, or the 

warranty period has expired; 

2)The damage is caused due to force majeure incidents, such as 

fire, flood, thunder and earthquake;

3)The damage is caused as a result of the user’s failure to 

follow the user’s manual on the use, maintenance and 

storage of the product.

Certificate of Quality

QC Passed    Approved for shipment

QA

PASS

4)The damage is caused due to the breakdown and repair of the 

device by non-authorized service personnel.

5)Normal wear or consumption of the product is found in its use. 
6)The product cannot be used due to the reason related to the 

user’s own internet connection and software problem.

After-sales QQ account: 2782597064 (nickname: iData after-sales)

Email: [email protected]

Official website: www.idataglobal.com 
Address: F11, Building B1, Wuxi (Binhu) National Sensing Information

Center, No.999, Gaolang East Road, Wuxi City, Jiangsu Province
To know more product information and download detailed instructions, 

visit the official website of iData. 
The supporting software and SDK for relevant functions help you better 

use the iData 80.

©

 2018 IDATA GLOBAL. All Rights Reserved.

2.4G WiFi:2412MHz~2472MHz 

5G WiFi Band 1: 5180MHz ~ 5240MHz 

5G WiFi Band 2: 5260MHz ~ 5320MHz 

2.4GHz WiFi: 17.67dBm(E.I.R.P.)

5GHz WiFi Band 1:16.76dBm(E.I.R.P.)

5GHz WiFi Band 2:16.93dBm(E.I.R.P.)

Band 1

TX:1920MHz ~ 1980MHz,RX:2110MHz~2170MHz

Band 3

TX:1710MHz ~ 1785MHz,RX:1805MHz~1880MHz

Band 7

TX:2500MHz ~ 2570MHz,RX:2620MHz~2690MHz

Band 8

TX:880MHz ~ 915MHz,RX:925MHz~960MHz

Band 20

TX:832MHz ~ 862MHz,RX:791MHz~821MHz

Band 38

TX:2570MHz ~ 2620MHz,RX: 2570MHz ~ 2620MHz

Band 40

TX:2300MHz ~ 2400MHz,RX:2300MHz ~ 2400MHz

22.69dBm

22.53dBm

22.40dBm

23.09dBm

23.49dBm

23.56dBm

23.20dBm

5745MHz ~ 5825MHz

13.23dBm (E.I.R.P.)

2402~2480MHz

BT4.0+EDR: 8.75dBm (E.I.R.P.)

BT4.0+BLE: -3.64dBm (E.I.R.P.)

E-GSM 900: 880~915MHz 

DCS 1800: 1710~1785MHz

E-GSM 900: 33.51dBm

DCS 1800: 29.54dBm

Band 1

TX:1920MHz~1980MHz,RX:2110MHz~2170MHz

Band 8 

TX:880MHz~915MHz, RX:925MHz~960MHz

Operation Frequency:
Maximum Power:

Operation Frequency:

Maximum Power:

Operation Frequency:

WIFI

Maximum Power:

13.56MHz

-30.06dBuA/m@10m

Operation Frequency:

Maximum Power:

Operation Frequency:

Operation Frequency:

Operation Frequency:

Maximum Power(LTE Band 1):

Maximum Power(LTE Band 3):

Maximum Power(LTE Band 7):

Maximum Power(LTE Band 8):

Maximum Power(LTE Band 20):

Maximum Power(LTE Band 38):

Maximum Power(LTE Band 40):

23.47dBm

23.30dBm

Maximum Power

(WCDMA Band 1)

Maximum Power

(WCDMA Band 8):

Maximum Power:

5.8G SRD

BT

GSM

WCDMA

NFC 

LTE

Manufacturer:

 

Wuxi iData Technology Company Ltd.

Address of 
Manufacturer:

 

Floor 11, Building B1, No.999 Gaolang East 

Road, Wuxi City, P.R.C.

1.Risk of explosion if battery is replaced by an incorrect type. 

Dispose of used batteries according to the instructions. 

2.Adapter shall be installed near the equipment and shall be 

easily accessible.

3.The product shall only be connected to a USB interface of 

version USB 2.0.

4.4.The operating temperature of the EUT can’t exceed 40℃ 

and shouldn’t be lower than -10℃.

5.Use careful with the earphone maybe 

possible excessive sound pressure from 

earphones and headphones can cause 

hearing loss.

 6.The device complies with RF specifications when the device 

used at 5mm from your body and 0mm from your head.

7.The UNII Band 1 indoor use only.

Hereby, Wuxi iData Technology Company Ltd. declares that 

this Smart Device product is in compliance with essential 

requirements and other relevant provisions of Directive 

2014/53/EU. This product is allowed to be used in all EU 

member states.

FCC Statement

15.19 Labeling requirements. 

This device complies with part 15 of the FCC Rules. Operation is subject 

to the following two conditions: (1) This device may not cause harmful 

interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation. 

15.21 Information to user. 

Any Changes or modifications not expressly approved by the party 

responsible for compliance could void the user's authority to operate 

the equipment. 

WiFi 5G does not support hotspot.

15.105 Information to user. 

This equipment has been tested and found to comply with the limits for 

a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates uses 

and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to 

radio communications. However, there is no guarantee that interference 

will not occur in a particular installation. If this equipment does cause 

harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged 

to try to correct the interference by one or more of the following 

measures: 
-- Reorient or relocate the receiving antenna.   
-- Increase the separation between the equipment and receiver.   
-- Connect the equipment into an outlet on a circuit different from that 

to which the receiver is connected.   
-- Consult the dealer or an experienced radio/TV technician for help. 

Specific Absorption Rate (SAR) information: 

This product meets the government's requirements for exposure to radio 

waves. The guidelines are based on standards that were developed by 

independent scientific organizations through periodic and thorough 

evaluation of scientific studies. The standards include a substantial 

safety margin designed to assure the safety of all persons regardless of 

age or health. 
FCC RF Exposure Information and Statement The SAR limit of USA (FCC) 

is 1.6 W/kg averaged over one gram of tissue. This device was tested for 

typical body-worn operations with the back of the handset kept 10mm 

from the body. To maintain compliance with FCC RF exposure 

requirements, use accessories that maintain a 10mm separation 

distance between the user's body and the back of the handset. The use 

of belt clips, holsters and similar accessories should not contain metallic 

components in its assembly. The use of accessories that do not satisfy 

these requirements may not comply with FCC RF exposure 

requirements, and should be avoided. 
Body-worn Operation
This device was tested for typical body-worn operations. To comply with 

RF exposure requirements, a minimum separation distance of 10mm for 

body worn must be maintained between the user’s body, including the 

antenna. Third-party belt-clips, holsters, and similar accessories used by 

this device should not contain any metallic components. Body-worn 

accessories that do not meet these requirements may not comply with 

RF exposure requirements and should be avoided. Use only the supplied 

or an approved antenna.

Summary of Contents for 50

Page 1: ...iData 50 Quick Guide ...

Page 2: ...bottom Earphone jack User defined function key Scan key Rear camera Primary scan key Back key Microphone Scanning indicator Earphone Scan lens Speaker Standard USB port Battery cover lock Scan key User defined function key Power key Flashlight Overview of iData 50 1 ...

Page 3: ...ush the battery cover lock to the right to lock the battery cover Lock 1 Push the battery to the bottom of the battery compartment and press it downwards Note The iData 50 adapts integrated design for the battery and battery cover ...

Page 4: ...attery 3 2 Pull up the battery cover from the groove at the upper end of the battery cover Unlock 1 Push the battery cover lock to the left Note The iData 50 adapts integrated design for the battery and battery cover ...

Page 5: ...ing a SIM Card Micro SIM Card SIM卡 SIM卡 1 Insert a SIM card by following the direction in the figure below 4 Note Micro SIM cards are applicable to the iData 50 After replacing a SIM card restart the iData 50 ...

Page 6: ...wards and insert a TF card as shown in the figure below 1 Push the card cover by following the OPEN direction marked on the card cover Note TF cards namely Micro SD cards are applicable to the iData 50 After replacing a TF card restart the iData 50 ...

Page 7: ...rd cover as shown in the figure below 4 Pull back the card cover by following the LOCK direction marked on the card cover 6 Note TF cards namely Micro SD cards are applicable to the iData 50 After replacing a TF card restart the iData 50 ...

Page 8: ...t the screen brightness to a small value by selecting Settings Display Brightness Disable functions that are not frequently used for example GPS Bluetooh Wi Fi and 3G communication Description of charging indicator When the battery is in the charging status the charging indicator is in red When the battery is fully charged the charging indicator is in green When the battery volume is low 1 a messa...

Page 9: ...purchased separately Charge the iData 50 for more than eight hours for the first time Do not contact battery electrodes by using metal objects for example keys or short circuit the battery electrodes Do not put the battery in an environment that is too hot too damp or corrosive Do not squeeze or collide the battery Do not store the battery on a long term basis when the battery is empty or is full S...

Page 10: ...le scanning do as follows Enabling the Scan Function 1 Click the iScan icon on the menu page 2 Click the blue slider on the right of Enable Barcode Scanning to enable the scanning function if you click the slider again the scanning function is disabled 3 Press the yellow key to scan a barcode When the scanning indicator becomes blue from red and a beep is heard the barcode is scanned successfully ...

Page 11: ...the menu page 2 Select WIRELESS NETWORKS More NFC 3 Click the blue slider on the right to enable NFC if you click the blue slider again NFC is disabled 4 Put an NFC card close to the back of the iData 50 After a beep is heard the card is read successfully NFC NFC induction area Network and Connection ...

Page 12: ...Data 50 cannot access the Internet Solution Make sure that the SIM card is not in arrears and that the SIM card is correctly inserted Troubleshooting After sales Service After sales QQ account 2782597064 nickname iData after sales Email support idataglobal com Official website www idataglobal com Address F11 Building B1 Wuxi Binhu National Sensing Information Center No 999 Gaolang East Road Wuxi Cit...

Page 13: ... The parts needed for the product repair service will be available for no more than 1 year after the product manufacturing ceases Note Reminder Please contact our customer service staff before sending any product to us Warranty of paid repair service You may choose to use our paid repair service under the following circumstances including but not limited to 1 There is no warranty card or the valid ...

Page 14: ...z 13 23dBm E I R P 2402 2480MHz BT4 0 EDR 8 75dBm E I R P BT4 0 BLE 3 64dBm E I R P E GSM 900 880 915MHz DCS 1800 1710 1785MHz E GSM 900 33 51dBm DCS 1800 29 54dBm Band1 TX 1920MHz 1980MHz RX 2110MHz 2170MHz Band8 TX 880MHz 915MHz RX 925MHz 960MHz Operation Frequency Maximum Power Operation Frequency Maximum Power Operation Frequency WIFI Maximum Power 13 56MHz 30 06dBuA m 10m Operation Frequency ...

Page 15: ...o a USB interface of version USB 2 0 4 4 The operating temperature of the EUT can t exceed 40 and shouldn t be lower than 10 5 Use careful with the earphone maybe possible excessive sound pressure from earphones and headphones can cause hearing loss 6 The device complies with RF specifications when the device used at 5mm from your body and 0mm from your head 7 The UNII Band 1 indoor use only Hereby...

Page 16: ...different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Specific Absorption Rate SAR information This product meets the government s requirements for exposure to radio waves The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies The ...

Reviews: