8
9
10
Note: iScan is used to scan barcodes. By default, iScan is
installed and scanning is enabled upon delivery of the device.
You can down the latest version from the following address:
http://t.cn/8k5hWCo
To start the iScan program and enable
scanning, do as follows:
Enabling the Scan Function
1. Click the iScan icon on the menu page.
2. Click the blue slider on the right of Enable Barcode Scanning to
enable the scanning function (if you click the slider again, the
scanning function is disabled).
3. Press the yellow key to scan a barcode. When the scanning
indicator becomes blue from red and a beep is heard, the barcode
is scanned successfully.
iScan
iScan
Back
Barcode scanning
To enable the NFC function, do as follows:
Enabling the NFC Function
1. Click the Settings icon on the menu page.
2. Select WIRELESS & NETWORKS/More > NFC.
3. Click the blue slider on the right to enable NFC (if you click the
blue slider again, NFC is disabled).
4. Put an NFC card close to the back of the iData 50. After a beep
is heard, the card is read successfully.
NFC
NFC induction area
Network and Connection
Battery Safety Instructions
Battery
The battery of the iData 50 is a polymer battery. The battery and
the battery cover are integrated.
Please use the charger specified by iData. Do not replace the
desktop stand or adapter at random.
When you first get the battery, the remaining battery volume may
be around 50%. You may charge the iData 50 by using the power
adapter delivered with the iData 50 or a desktop stand (to be
purchased separately). Charge the iData 50 for more than eight
hours for the first time.
Do not contact battery electrodes by using metal objects, for
example, keys, or short circuit the battery electrodes.
Do not put the battery in an environment that is too hot, too damp
or corrosive. Do not squeeze or collide the battery.
Do not store the battery on a long-term basis when the battery is
empty or is full. Store the battery when the battery volume is
around 50%.
If you will not use the iData 50 for a long time, please take out the
battery from the iData 50.
If the battery swells or expands, please replace the battery in time.
1. Fault: The iData 50 cannot be powered on.
Solution: Charge the iData 50.
2. Fault: After the iData 50 is connected to the charger, the charging
identifier is not displayed.
Solution: Charge the iData 50 continuously for one hour. If the
charging identifier is still not displayed, contact iData after-sales
service personnel.
3. Fault: Charging is slow.
Solution: Make sure you use the original accessory for charging.
4. Fault: After a SIM card is inserted, the iData 50 cannot access the
Internet.
Solution: Make sure that the SIM card is not in arrears and that the
SIM card is correctly inserted.
Troubleshooting
After-sales Service
iData series product warranty card
Dear customer,
Thank you for choosing iData product. You may enjoy the following
services after buying iData product:
【Warranty of free repair service】
1)12-month warranty is given to the device and battery and
3-month warranty is given to other accessories from the day
of purchase against functional failure that is not caused due to
manmade damage.
2)Our after-sale service department will mail out the repaired
device within 24 hours after the device with any problem is
received, so as to keep you wait for the shortest possible time.
3)A device of the same model will be provided free of charge for
replacement of the device that cannot be used normally after
being returned for repair due to the same problem for 3 times
in 1 year.
The parts needed for the product repair service will be available for
no more than 1 year after the product manufacturing ceases.
Note:
Reminder:
Please contact our customer service staff before sending any product
to us.
【Warranty of paid repair service】
You may choose to use our paid repair service under the following
circumstances (including but not limited to):
1)There is no warranty card, or the valid invoice is missing, or the
warranty period has expired;
2)The damage is caused due to force majeure incidents, such as
fire, flood, thunder and earthquake;
3)The damage is caused as a result of the user’s failure to
follow the user’s manual on the use, maintenance and
storage of the product.
Certificate of Quality
QC Passed Approved for shipment
QA
PASS
4)The damage is caused due to the breakdown and repair of the
device by non-authorized service personnel.
5)Normal wear or consumption of the product is found in its use.
6)The product cannot be used due to the reason related to the
user’s own internet connection and software problem.
After-sales QQ account: 2782597064 (nickname: iData after-sales)
Email: [email protected]
Official website: www.idataglobal.com
Address: F11, Building B1, Wuxi (Binhu) National Sensing Information
Center, No.999, Gaolang East Road, Wuxi City, Jiangsu Province
To know more product information and download detailed instructions,
visit the official website of iData.
The supporting software and SDK for relevant functions help you better
use the iData 80.
©
2018 IDATA GLOBAL. All Rights Reserved.
2.4G WiFi:2412MHz~2472MHz
5G WiFi Band 1: 5180MHz ~ 5240MHz
5G WiFi Band 2: 5260MHz ~ 5320MHz
2.4GHz WiFi: 17.67dBm(E.I.R.P.)
5GHz WiFi Band 1:16.76dBm(E.I.R.P.)
5GHz WiFi Band 2:16.93dBm(E.I.R.P.)
Band 1
TX:1920MHz ~ 1980MHz,RX:2110MHz~2170MHz
Band 3
TX:1710MHz ~ 1785MHz,RX:1805MHz~1880MHz
Band 7
TX:2500MHz ~ 2570MHz,RX:2620MHz~2690MHz
Band 8
TX:880MHz ~ 915MHz,RX:925MHz~960MHz
Band 20
TX:832MHz ~ 862MHz,RX:791MHz~821MHz
Band 38
TX:2570MHz ~ 2620MHz,RX: 2570MHz ~ 2620MHz
Band 40
TX:2300MHz ~ 2400MHz,RX:2300MHz ~ 2400MHz
22.69dBm
22.53dBm
22.40dBm
23.09dBm
23.49dBm
23.56dBm
23.20dBm
5745MHz ~ 5825MHz
13.23dBm (E.I.R.P.)
2402~2480MHz
BT4.0+EDR: 8.75dBm (E.I.R.P.)
BT4.0+BLE: -3.64dBm (E.I.R.P.)
E-GSM 900: 880~915MHz
DCS 1800: 1710~1785MHz
E-GSM 900: 33.51dBm
DCS 1800: 29.54dBm
Band 1
TX:1920MHz~1980MHz,RX:2110MHz~2170MHz
Band 8
TX:880MHz~915MHz, RX:925MHz~960MHz
Operation Frequency:
Maximum Power:
Operation Frequency:
Maximum Power:
Operation Frequency:
WIFI
Maximum Power:
13.56MHz
-30.06dBuA/m@10m
Operation Frequency:
Maximum Power:
Operation Frequency:
Operation Frequency:
Operation Frequency:
Maximum Power(LTE Band 1):
Maximum Power(LTE Band 3):
Maximum Power(LTE Band 7):
Maximum Power(LTE Band 8):
Maximum Power(LTE Band 20):
Maximum Power(LTE Band 38):
Maximum Power(LTE Band 40):
23.47dBm
23.30dBm
Maximum Power
(WCDMA Band 1)
Maximum Power
(WCDMA Band 8):
Maximum Power:
5.8G SRD
BT
GSM
WCDMA
NFC
LTE
Manufacturer:
Wuxi iData Technology Company Ltd.
Address of
Manufacturer:
Floor 11, Building B1, No.999 Gaolang East
Road, Wuxi City, P.R.C.
1.Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
2.Adapter shall be installed near the equipment and shall be
easily accessible.
3.The product shall only be connected to a USB interface of
version USB 2.0.
4.4.The operating temperature of the EUT can’t exceed 40℃
and shouldn’t be lower than -10℃.
5.Use careful with the earphone maybe
possible excessive sound pressure from
earphones and headphones can cause
hearing loss.
6.The device complies with RF specifications when the device
used at 5mm from your body and 0mm from your head.
7.The UNII Band 1 indoor use only.
Hereby, Wuxi iData Technology Company Ltd. declares that
this Smart Device product is in compliance with essential
requirements and other relevant provisions of Directive
2014/53/EU. This product is allowed to be used in all EU
member states.
FCC Statement
15.19 Labeling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
15.21 Information to user.
Any Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate
the equipment.
WiFi 5G does not support hotspot.
15.105 Information to user.
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Specific Absorption Rate (SAR) information:
This product meets the government's requirements for exposure to radio
waves. The guidelines are based on standards that were developed by
independent scientific organizations through periodic and thorough
evaluation of scientific studies. The standards include a substantial
safety margin designed to assure the safety of all persons regardless of
age or health.
FCC RF Exposure Information and Statement The SAR limit of USA (FCC)
is 1.6 W/kg averaged over one gram of tissue. This device was tested for
typical body-worn operations with the back of the handset kept 10mm
from the body. To maintain compliance with FCC RF exposure
requirements, use accessories that maintain a 10mm separation
distance between the user's body and the back of the handset. The use
of belt clips, holsters and similar accessories should not contain metallic
components in its assembly. The use of accessories that do not satisfy
these requirements may not comply with FCC RF exposure
requirements, and should be avoided.
Body-worn Operation
This device was tested for typical body-worn operations. To comply with
RF exposure requirements, a minimum separation distance of 10mm for
body worn must be maintained between the user’s body, including the
antenna. Third-party belt-clips, holsters, and similar accessories used by
this device should not contain any metallic components. Body-worn
accessories that do not meet these requirements may not comply with
RF exposure requirements and should be avoided. Use only the supplied
or an approved antenna.
Summary of Contents for 50
Page 1: ...iData 50 Quick Guide ...