5.18 Low Label Detection Verification
Once the low label sensor is installed, it is necessary to verify correct operation. To test
for correct operation, place the unwind assembly inner flange in a position to block the
low label sensor beam. Press the jog icon and verify that no low label indication is
shown (Use of a three stage beacon or system status output is required). Rotate the
flange until the low label sensor beam is not blocked. As soon as the low label sensor is
not covered, the Low Label condition is set and is indicated by the appropriate output
signal. If the low label sensor is again blocked and remains blocked after five label feeds
via the jog or product sensor triggers, the low label signal is reset. Alternatively, the low
label condition will reset when the printer is changed from an offline to an online state.
No low label indication would be present at the three stage beacon or system status
outputs.
Summary of Contents for 252
Page 1: ...Model 252 Label Printer Applicator Operator Technical Manual...
Page 10: ...I GENERAL...
Page 19: ...II OPERATING FUNDAMENTALS...
Page 25: ...III INITIAL SETUP...
Page 28: ...Model 252 Label Printer Applicator Operators Technical Manual 3 1 12 Declaration of Conformity...
Page 116: ...Model 252 Label Printer Applicator Operators Technical Manual 0 V DRAWINGS AND DIAGRAMS...
Page 160: ...VI COMPONENT INFORMATION...
Page 161: ...Model 252 Label Printer Applicator Operators Technical Manual 1 MiniBeam Photocell...
Page 162: ...Model 252 Label Printer Applicator Operators Technical Manual 2...
Page 163: ...Model 252 Label Printer Applicator Operators Technical Manual 3...
Page 164: ...Model 252 Label Printer Applicator Operators Technical Manual 4...