Specifications of the (3) mechanical relays:
Single side stable, S Type 1 Form C
Minimum operating power – approximately 100mW
Nominal operating power – approximately 200mW
Contact
:
Arrangement - 1 Form C (Part No. - DS1E-S-DC5V)
Initial contact resistance, max. (by voltage drop 6 V DC 1A) - 50m
Ω
Contact Material – Gold-clad silver
Rating (restive) – Max. switching power – 60 W, 125 VA
Max. switching voltage – 220 V DC, 250 V AC
Max. switching current – 2 A DC, AC
Max. carrying current – 3 A DC, AC
Expected Life (min. operations – Mechanical (at 600 cpm) 10
8
Electrical 2 A 30 VDC resistive – 5 X10
5
Coil
(polarized) (at 20
o
C (68
o
F) ):
Nominal Voltage, 5V DC
Minimum Operating Power - Approx. 100mW
Nominal Operating Power - Approx. 200mW
Characteristics
(at 20
o
C 68
o
F):
Max.
Operating
Speed
– 20cpm at rated load 50 cps at low level load
Initial insuration resistance – Min. 100M
Ω
(at 500 VDC)
Initial
break-down
voltages (Detection current: 10mA)
Between
open
Contacts
-
500Vrms
Between
contacts
sets
-
n/a
Between contacts and coil -
1,000Vrms
FCC surge voltage between contacts and coil – 1,500Vrms
Operate
time
(at nominal voltage)(excluding contact bounce time)
–
approx. 3ms
Release
time
(without diode)(at nominal voltage
) – approx. 2 ms
Set Time
(at nominal voltage) (excluding contact bounce time)
–
approx. 3ms
Reset
Time
(at nominal voltage) (excluding contact bounce time)
–
approx. 3ms
Temperature
rise
(at nominal voltage) (Contact current 2A)
–
Max. 65
o
C
Shock resistance: Functional – Min. 490 m/s
2
{50 G}
Destructive – Min. 294 m/s
2
{30 G}
Vibration resistance: Functional – 10 to 55Hz at double amplitude of 3.3mm
Destructive - 10 to 55Hz at double amplitude of 5mm
Unit weight - approx. 3.2g (.11 oz.)
Conditions for operation, transport and storage (not freezing and
condensing at low temperature): Ambient temperature –
-
40
o
C to
+
70
o
C
(
-
40
o
F to
+
158
o
F)
Humidity
–
5
to
85%
R.H.
Summary of Contents for 250
Page 1: ...250 Print and Apply Operator Technical Manual Model...
Page 69: ...Model 250 Printer Applicator Operators Technical Manual Section 3B Section 3B Page 9 of 9...
Page 110: ...Model 250 Printer Applicator Operators Technical Manual Section Six Section 6 Page 17 of 20...
Page 111: ...Model 250 Printer Applicator Operators Technical Manual Section Six Section 6 Page 18 of 20...
Page 112: ...Model 250 Printer Applicator Operators Technical Manual Section Six Section 6 Page 19 of 20...
Page 127: ...2051 FRANKLIN DR FORT WORTH TX 76106 250 PRECISION TILT...