background image

Manual IB-1922MF-C32

Manual IB-1922MF-C32

Installation

Important: 

During the drive assembly all cabling has to be disconnected from 

the computer. Otherwise it may cause electric shock accident or malfunction. 
When inserting the hard drives, be aware of possible electrostatic discharge as 
this can cause damage or malfunction. Please touch a "grounded" metal object 
or wear antistatic gloves before installation.

Attention!

• The PCB, drive and SSDs are very sensitive components. Please insert the 

drive carefully and make sure it is aligned correctly.

• Be careful, as there are sharp edges inside the device to avoid injury!
• In order to prevent data loss, it is imperative that a backup of hard disks 

containing data is made beforehand.

1.

  Unscrew the four screws as 

displayed and open the top 
cover. 

2.

  Insert your SSD carefully with 

the connection side into the 
M.2 socket at an angle of 
about 30° so it fits in smoothly.

3.

  Then push the SSD card down 

and fix the M.2 nut with the 
screw as displayed and place 
the delivered thermal pad 
directly to the M.2 NVMe 
SSD.

Summary of Contents for IB-1922MF-C32

Page 1: ...Manual IB 1922MF C32 USB Type C Enclosure for M 2 NVMe SSD Handbuch IB 1922MF C32 Externes USB Type C Gehäuse für M 2 NVMe SSD ...

Page 2: ...ucting parts Do not bring plug contacts in contact with pointed and metal objects Use in intended environments only Operate the device using a power unit meeting the specifications of the type plate only Keep the device power unit away from humidity liquid vapour and dust Do not modify the device Do not connect the device during thunderstorms Approach specialist retailers if you require repairs 2 ...

Page 3: ...ice prior to cleaning Aggressive or intense cleaning agents and solvents are unsuitable Make sure there is no residual moisture after cleaning We recommend cleaning devices using a dry anti static cloth 7 Disposing of the device Environmental pollution unsuitable for recycling Potential environmental pollution caused by components recycling circle interrupted This icon on product and packaging ind...

Page 4: ...ntakt mit Spannungsführenden Komponenten vermeiden Steckkontakte nicht mit spitzen und metallischen Gegenständen berühren Verwendung nur in dafür vorgesehenen Umgebungen Gerät ausschließlich mit Typenschildkonformen Netzteil betreiben Gerät Netzteil fern von Feuchtigkeit Flüssigkeit Dampf und Staub halten Eigenständige Modifikationen sind unzulässig Gerät nicht während eines Gewitters anschließen ...

Page 5: ...ußer Betrieb nehmen aggressive bzw scharfe Reinigungs und Lösungsmittel sind ungeeignet nach der Reinigung sicherstellen dass keine Restfeuchtigkeit vorhanden ist Reinigung der Geräte am besten mit trockenem Antistatiktuch durchführen 7 Entsorgung des Gerätes Umweltverschmutzung Wiederverwertung nicht möglich Mögliche Umweltbelastung durch Bestandteile Recyclingkreislauf unterbrochen Dieses auf de...

Page 6: ...plies the full data transfer rate of up to 20 Gbit s via a USB 3 2 Gen 2x2 Type C host interface and an available Asmedia chipset ASM3264 in your host PC Currently a macOS based computer does not support the USB 3 2 Gen 2x2 standard A USB Type A host interface can be connected with USB 3 1 3 0 or 2 0 standard in some notebooks and computers and can be used with the related data transfer rate via a...

Page 7: ...so making your M 2 SSD more durable and more efficient With the IB 1922MF C32 sensitive data can now be protected against changes and can be released again via a switch With a small hand movement the switch on the IB 1922MF C32 can be moved to the desired position Click Safe Packing content 1x IB 1922MF C32 1x Type C to Type C cable 1x screw driver 1x screw for M 2 installation 1x silicone thermal...

Page 8: ... SSDs are very sensitive components Please insert the drive carefully and make sure it is aligned correctly Be careful as there are sharp edges inside the device to avoid injury In order to prevent data loss it is imperative that a backup of hard disks containing data is made beforehand 1 Unscrew the four screws as displayed and open the top cover 2 Insert your SSD carefully with the connection si...

Page 9: ...f the write protection mode will only be activated when the device has been disconnected and then reconnected to the host computer Cooling fan Fan with intelligent temperature control by built in IC chipset If the temperature of the device rises above 40 C the fan starts automatically If the temperature of the device falls below 40 C the fan stops automatically Manual IB 1922MF C32 4 Carefully rei...

Page 10: ... A drive must be initialized and must have active partitions to be immedia tely recognized as a volume in the operating system If this is not the case initialize the drive in the volume management of your operating system If the drive is not recognized instantly by the operating system please check if the driver software is installed USB if the SSD is initialized partitioned and formatted Manual I...

Page 11: ... Hostschnittstellen und einem zur Verfügung stehenden Asmedia Chipsatz ASM3264 die volle Datenübertragungsrate von bis zu 20 Gbit s Derzeit wird der USB 3 2 Gen 2x2 Standard nicht von einem macOS basierten Computer unterstützt Eine USB Type A Hostschnittstelle kann in einigen Notebooks und PCs mit USB 3 1 3 0 oder 2 0 angebunden sein und ebenfalls mit der jeweiligen Datenübertragungsrate Verwendun...

Page 12: ... vor Veränderungen geschützt und wieder freigegeben werden Mit einer kleinen Handbewegung lässt sich der dafür zuständige Schalter des IB 1922MF C32 in die gewünschte Position bewegen Klick Sicher Verpackungsinhalt 1x IB 1922MF C32 1x USB Type C zu Type C Kabel 1x Schraubendreher 1x Schraube für M 2 Installation 1x Silikon Wärmeleitpad 1x Schnellinstallationsanleitung Hauptmerkmale Hochwertiges Al...

Page 13: ...werk bitte vorsichtig ein und achten Sie auf die richtige Ausrichtung Gehen Sie behutsam vor da im Inneren des Gerätes scharfe Kanten vorhan den sind Um Datenverlust vorzubeugen sollte zwingend von Festplatten mit enthalte nen Daten zuvor ein Backup durchgeführt werden 1 Lösen Sie die vier Schrauben wie gezeigt und öffnen Sie den Deckel 2 Platzieren Sie Ihre SSD vor sichtig mit der Anschlussseite ...

Page 14: ...folgt nur wenn das Gerät getrennt und dann wieder mit dem Hostcomputer verbunden wurde Lüfter Lüfter mit intelligenter Temperaturkontrolle durch eingebauten IC Chipsatz für die Temperatur kontrolle Steigt die Temperatur des Gerätes über 40 C an startet der Lüfter automatisch Unterschreitet die Temperatur des Gerätes 40 C stoppt der Lüfter automatisch Handbuch IB 1922MF C32 4 Installieren Sie nun d...

Page 15: ...partitioniert und formatiert werden um vom System angezeigt zu werden Wenn die SSD nicht sofort vom System erkannt wird bitte prüfen ob die Treibersoftware installiert ist USB ob die SSD initialisiert partitioniert und formatiert ist Bitte das Ende von Schreib und Lesevorgängen abwarten bevor ein angeschlossenes Gehäuse vom Rechner getrennt wird um Datenverlust zu vermeiden Handbuch IB 1922MF C32 ...

Page 16: ...ithout prior notice The diagrams contained in this manual may also not fully represent the product that you are using and are there for illustration purposes only RaidSonic Technology GmbH assumes no responsibility for any differences between the product mentioned in this manual and the product you may have Microsoft Windows and the Windows logo are registered trademarks of Microsoft Corporation A...

Reviews: