ULTRA ARM INSTALLATION - rev 04/22/14 pjm
Page 2 of 4
ATTACH POLE CLAMP TO POLE
Using the 1/4” hex key,
separate the two halves of
pole mount as shown, place
around pole at the desired
height and reassemble.
IF MOUNTING TO A POLE
ATTACH RADIUS MOUNT TO POLE
Using a 1/8”
hex key wrench
make sure the
set screws in the
radius
mount
are pulled out
enough
that
the mount will
easily
slide
down over the
pole.
Tighten
the set screws.
OR
ATTACH UL500 TO W2
Attach to UL500 to W2 wall
mount using 3/8 bolt assembly
and 1” bearing assembly
provided. Insert bolt assembly up
through wall ear. Place 1” bearing
assembly over bolt on other side
of wall ear. Place UL500 over bolt
and bearing and turn bolt until
UL500 is secure and smoothly
turns against the bearing.
Beauty
cap
UL500
W2
1” ID bearing
assembly
3/8 bolt
assembly with
3/8 ID bearing
ATTACH UL510 TO W2
Attach to UL510 to W2 wall
mount using 3/8 bolt assembly
and 1” bearing assembly
provided. Insert bolt assembly
up through wall ear. Place 1”
bearing assembly over bolt on
other side of wall ear. Place
UL510 over bolt and bearing
and turn bolt until UL510 is
secure and smoothly turns
against the bearing.
1” ID bearing
assembly
3/8 bolt
assembly with
3/8 ID bearing
Beauty
cap
UL510
W2
ATTACH PARALINK TO W2
Attach to Paralink to W2 wall
mount using 3/8 bolt assembly
and 1” bearing assembly
provided. Insert bolt assembly
up through wall ear. Place 1”
bearing assembly over bolt on
other side of wall ear. Place
Paralink over bolt and bearing
and turn bolt until Paralink is
secure and smoothly turns
against the bearing.
Beauty
cap
Paralink
W2
1” ID bearing
assembly
3/8 bolt
assembly with
3/8 ID bearing
ATTACH WALL PLATE TO WALL
Locate the stud and mark the top hole,
drill 11/64 pilot hole and insert #14
screw and tighten slightly. Using a
level, mark the lower hole and drill pilot
hole, insert #14 screw and, with the
unit level, tighten both screws.
NOTE: ICW supplies #14 wood screws. If
installing onto metal studs, you will need to
replace with proper metal stud fasteners.
W2
W3
IF MOUNTING
TO A WALL