background image

ULTRA, UL180 & UL182 ARM INSTALLATION

ULTRA 180 & 182 ARM INSTALLATION - rev 11/22/17

Page 4 of 4

Ultra Arm Cable Management

Adjusting Rotation Limits

Adjusting Arm Tension

ADJUST ARM TENSION

Using the 3/16” T-handle  

hex wrench provided, turn  

the screw in the UL180/182 

arm clockwise to lighten  

the arm’s load resistance, 

 

or counter-clockwise  

to increase the load  

resistance. The arm  

must be horizontal  

before adjusting.

IMPORTANT

Extend the UL180 or UL182 straight out and be 

sure all equipment is mounted on the arm before 

adjusting the arm’s resistance. Use the T-handle 

provided to adjust the arms’ resistance. Do not  

use power tools to adjust.

DO NOT ADJUST THE ARM TO SUPPORT 

MORE THAN 32 LBS. DOING SO MAY 

DAMAGE THE ARM.

Adjusting 

rotation limits 

for the standard 

Ultra Arm

 

Place Stop Pins  

as shown. The  

Stop Pin is built into 

the arm rather than 

into the wall ear.

ULTRA CABLE MANAGEMENT

• 

Prepare all cables to route within the arm by placing them 

near cavity of arm and bundling together if necessary. 

• 

Remove cover by unscrewing four Phillips head cap screws. 

Screws are captured by the cover so they cannot fall out. 

Once screws are disengaged, pull cover out of arm.

• 

Place cables within the channel. Do not block the holes 

where screws will engage in arm.

• 

Replace cover and tighten screws. Cables should be  

able to pull through to desired position if necessary.