PRT-RDE2-PCB
Protege Ethernet 2 Reader Expander
Installation Manual | June 2017
29
6.3
PGM Beeper Outputs Special Functions (5 and 8)
The PGM beeper outputs 5 and 8 on the provide special diagnostic information when a card is presented. The
following table shows the beeper modes of operation.
Function
Description
2 Beeps
Access Granted. The lock will activate and allow access to the door the card has been
presented.
4 Beeps
Offline Access Granted. This is generated ONLY if the is operating offline and the mode
of offline operation allows access.
1 Long Beep
Offline Access Denied. This is generated ONLY if the is operating offline and the mode
of offline operation prevents this card from being allowed access.
1 Long Beep
1 Short Beep
Access Denied Card Number Not Known. The card number is not known in the system.
The card that has been presented to the reader could not be matched to a valid user in
the system.
1 Long Beep
2 Short Beeps
Access Denied Door Group. The user is denied access because they do not have
access to the door. This error will also be generated if the door group is not set or the
door group schedule is not valid.
1 Long Beep
3 Short Beeps
Access Denied Area Group. The user is denied access because they do not have
access to the area that is being controlled by the door. If the area that the door is
associated with is armed, and the user does not have this area in their area disarm
group, they will be denied access. This also depends on the area group settings for the
door.
1 Long Beep
4 Short Beeps
Access Denied Access Level. The user is denied access because they do not have a
valid access level or the access level they are assigned is currently outside the
programmed schedule.