Stay Arming an Area
Stay arming is an option that must be enabled by your installer.
This method of arming allows you to remain in the area while it's partially armed. Stay areas are inputs that are
bypassed when the system is stay armed. For example, if you are working late and the stay option is enabled, you
can arm a portion of the building to protect the windows and doors without arming other inputs.
1.
From the Arm/Disarm menu you will be shown the area(s) associated with the keypad and its current status.
Select the area you want to stay arm.
Office
is DISARMED
2.
Press
[STAY]
to enable the normal inputs in the area and bypass the stay areas.
Office
Enabling input(s)
3.
The system then checks the inputs in the area are closed.
Office
Checking input(s)
4.
If all the inputs are closed, the arming process completes.
Office
Arm complete
5.
The area then goes into exit delay.
Office
in EXIT delay
6.
Once the exit delay time has elapsed, the area is stay armed.
Office
is STAY
Instant Stay Arming an Area
Instant stay arming is an option that must be enabled by your installer.
Instant stay arming reduces the exit delay to 1 second, and inputs which normally initiate the entry delay will
instead set off the alarm immediately (i.e. all inputs are treated as '
instant
'). This is commonly used at night while
residents are in bed, so that any intruder entering the building will set off the alarm immediately.
To instant stay arm the area, hold down the
[STAY]
key for 2 seconds, or press the
[STAY]
key a second time
while the area is in exit delay.
PRT-KLCD | Protege Alphanumeric LCD Keypad | User Manual
15