ICT Protege 5 Installation Manual Download Page 14

Technical Specifications

The following specifications are important and vital to the correct operation of this product. Failure to adhere to
the specifications will result in any warranty or guarantee that was provided becoming null and void.

Ordering Information

PRT-TS50-TH-B

Protege 5" Touchscreen (Black)

PRT-TS50-TH-W

Protege 5" Touchscreen (White)

Power Supply

Operating Voltage

11-14VDC

Operating Current

130mA (150mA Max)

User Interface

User Interface Display

480 x 800 Color LCD display

User Input

5" capacitive touchscreen

Dimensions

Dimensions (L x W x H)

131 x 90 x 15mm (5.15 x 3.54 x 0.59”)

Net Weight

160g (5.6oz)

Operating Conditions

Operating Temperature

-10° to 60°C (14° to 140°F)

Storage Temperature

-10˚ to 85˚C (14˚ to 185˚F)

Humidity

0%-93% non-condensing, indoor use only (relative humidity)

It is important that the unit is installed in a dry cool location that is not affected by humidity. Do not locate the unit
in air conditioning or a boiler room that can exceed the temperature or humidity specifications.

Integrated Control Technology continually strives to increase the performance of its products. As a result these
specifications may change without notice. We recommend consulting our website (www.ict.co) for the latest
documentation and product information.

PRT-TS50-TH | Protege 5" Touchscreen | Installation Manual

14

Summary of Contents for Protege 5

Page 1: ...PRT TS50 TH Protege 5 Touchscreen Installation Manual...

Page 2: ...onic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege and the Pr...

Page 3: ...uetooth Wireless Technology 9 Addressing the Touchscreen 10 Trouble Inputs 10 Error Messages 10 Operation 11 Using the Touchscreen 11 Touchscreen Settings 11 Open Doors 12 Technical Diagram 13 Technic...

Page 4: ...m The room controller connects to a vertical fan coil air conditioning unit to provide automated and energy efficient heating and cooling The current features of the touchscreen include Temperature vi...

Page 5: ...tion Requirements This equipment is to be installed in accordance with The product installation instructions The Local Authority Having Jurisdiction AHJ PRT TS50 TH Protege 5 Touchscreen Installation...

Page 6: ...ear case half against the wall and mark the mounting holes and cable entry area The cable entry area should align with a hole cut through the plaster wall board Cables are intended to be run inside th...

Page 7: ...ect the cable shield to a suitable earth point Do not connect the cable shield to a ground or AUX connection Do not terminate the touchscreen shield wire inside the touchscreen Important The touchscre...

Page 8: ...device Power supply and network communications connection EOL ON EOL OFF PURPLE SB YELLOW SA BLUE Output BROWN Input 2 ORANGE Input 1 WHITE NB GREEN NA BLACK 0V RED 12V SHIELD 12V 0V RS 485 NA RS 485...

Page 9: ...EOL End of Line jumper should be placed in the ON position when the keypad is inserted as the first or last module on the RS 485 network EOL Jumper OFF EOL Jumper ON Bluetooth Wireless Technology The...

Page 10: ...ction Default Trouble Group Default Trouble Group Option AEXXX 01 Module Tamper Opens when the touchscreen is removed from the wall System Module Tamper AEXXX 02 07 Reserved AEXXX 08 Module Offline Th...

Page 11: ...urn the air conditioning on or off Error message If there is an error message it will be displayed beneath the On Off button For more information see Error Messages previous page Mode Select the air c...

Page 12: ...he air conditioning when specific doors and windows are open If a door is open you will see the message Balcony door left open Close the door to keep the air conditioning running After 5 minutes the t...

Page 13: ...essential details needed to help ensure the correct installation of the touchscreen 42 80 85 60 20 09 4 57 84 00 9 0 4 5 9 0 4 5 9 4 5 42 80 32 50 32 50 10 30 10 30 63 32 63 32 63 32 40 77 42 80 42 80...

Page 14: ...31 x 90 x 15mm 5 15 x 3 54 x 0 59 Net Weight 160g 5 6oz Operating Conditions Operating Temperature 10 to 60 C 14 to 140 F Storage Temperature 10 to 85 C 14 to 185 F Humidity 0 93 non condensing indoor...

Page 15: ...interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a c...

Page 16: ...CES 003 This class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada CAN ICES 3 B NMB 3 B PRT TS50 TH Protege 5 Touchscr...

Page 17: ...yees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced developme...

Page 18: ...aimer Whilst every effort has been made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to...

Reviews: