BASIC SETUP

This page allows you to configure the basic settings of the panel.  To save any changes to the basic 

settings, click on 

Save Settings

 at the bottom of this page.

PANEL INFO

Site Name:

 Allows you to assign a custom name to the panel.

Model:

 Displays the model number of the panel.

OUTPUTS

Label:

 Allows you to assign a custom name to each individual output. The output names are displayed 

on the 

Status & Control

 page, as well as on the LCD screen.

Load-Shedding: 

Allows you to turn on load-shedding for each individual output. Load-shedding 

automatically disables DC power to the output when the panel’s system under-voltage alarm is 

triggered. The under-voltage threshold is set on the 

Alarm Setup

 page.

The panel must remain in an under-voltage condition for at least 30 seconds before the output will be 

disabled. This is to prevent the outputs from being disabled prematurely during a power surge.

Load-Shedding Auto Recovery: 

If this box is checked, outputs that have load-shedding turned on will 

automatically be enabled after panel’s system under-voltage alarm is cleared. The system under-

voltage alarm must remain cleared for at least 60 seconds before the outputs will be enabled. If this box 

is unchecked, outputs will need to be manually re-enabled after load-shedding is triggered.

Send Load-Shedding E-mail:

 If this box is checked, an e-mail alarm notification will be sent when 

outputs are automatically enabled or disabled by the load-shedding setting. The e-mail settings on the 

Network Setup 

page must be configured correctly before e-mail notifications can be sent.

Power Cycle: 

Allows you to turn on power-cycling for each individual output. When Power-Cycling is 

enabled for an output, the output will automatically be re-enabled after a selectable period of time after 

it is disabled from the 

Status & Control 

page. Power-Cycling is useful for remotely resetting power to 

hardware that is needed for network connectivity to the panel. 

The 

Sequence / Cycle Delay 

field controls the period of time that the output remains disabled before it 

is re-enabled. The Power Cycle setting will have no effect if no time delay is entered in the 

Sequence / 

Cycle Delay 

field. 

If multiple outputs with Power-Cycling enabled are disabled from the 

Status & Control 

page at the 

same time, they will be re-enabled in sequence.

10

Summary of Contents for ICT180-12IRC

Page 1: ...THE76 9OF9 30 030 0 0 90 065 7 5 3 ICT180 12IRC INTELLIGENT MODEL 0556 0 09 0 5636 3 INSTRUCTION MANUAL WITH REMOTE POWER CONTROL...

Page 2: ......

Page 3: ...sed Configuration Utility Page 8 Status Page 9 Basic Setup Page 10 Network Setup Page 12 Alarm Setup Page 13 User Setup Page 15 Maintenance Page 15 Password Reset Page 16 Router Configuration Page 16...

Page 4: ...fuses fully Refer to product specifications for maximum torque for the connectors Use appropriate wire size for both input and output connections Connect chassis of the unit to an Earth ground point...

Page 5: ...tected Ethernet communications port on the back of the panel The panel has a built in web server with an embedded web based GUI that can be accessed using any standard commercial web browser such as I...

Page 6: ...ack set up install panel on the rack using appropriate size screws and star washers on all four mounting holes If equipment rack is not electrically connected to Earth ground connect a ground cable fr...

Page 7: ...labeled 6 Re install plastic shield s to the output terminal block s and plastic caps to the input studs 7 For form C alarm monitoring connect an external alarm circuit to the alarm connector located...

Page 8: ...lown or missing fuse Activate Alarm Form C Contact is checked System Voltage is below the set value Activate Alarm Form C Contact is checked System voltage is above the set value Open Closed Activate...

Page 9: ...et on the Alarm Setup page Line 4 Displays the system current Current display will blink if the system current exceeds the Over Current Threshold set on the Alarm Setup page NETWORK SCREEN Line 1 Disp...

Page 10: ...the location address field of the browser If the panel is connected to a network with a DHCP server the panel will be assigned an IP address automatically To find the current IP address of the panel...

Page 11: ...uously refresh automatically When viewing this page through an encrypted HTTPS connection you will need to refresh the on screen display manually by clicking on the Status Control menu button or refre...

Page 12: ...ge alarm is cleared The system under voltage alarm must remain cleared for at least 60 seconds before the outputs will be enabled If this box is unchecked outputs will need to be manually re enabled a...

Page 13: ...ntered in the Sequence Cycle Delay field IP Address Enter the remote IP address you would like to monitor This field is optional if left blank the Network Watchdog will instead monitor the Gateway IP...

Page 14: ...the IP address of the Primary DNS Server for your network Secondary DNS Specify the IP address of the Secondary DNS Server for your network WEB SERVER WARNING Changing these ports may affect your abi...

Page 15: ...e the e mail notifications enter it here If this field is used a valid e mail address must also be entered in the To E mail Address 1 field SMTP User Name If your SMTP server requires a user name and...

Page 16: ...nd E mail If this box is checked an e mail alarm notification will be sent when the system under voltage alarm is triggered The e mail settings on the Network Setup page must be configured correctly b...

Page 17: ...uts or change settings New Password Allows you to change the password for the selected user Confirm New Password When changing a password you must re enter the new password here to confirm Administrat...

Page 18: ...ding screen In the Linksys WRT54G this is located in the Applications and Gaming tab The location of port forwarding may be different on other routers consult your router manual for instructions 2 To...

Page 19: ...g repeat steps 2a 2e with the HTTPS port number that the panel is using If you are using the default panel port settings the HTTPS port number is 443 4 To set up your router to allow remote panel firm...

Page 20: ...type the WAN IP Address of the router in the location address field of your browser followed by a colon and the HTTP port number that the panel is using e g http 209 123 10 33 8000 for IP Address 209...

Page 21: ...elds For example to send a text message to an AT T phone enter cellnumber txt att net replacing cellnumber with your cell phone number Here are some address formats for other mobile phone providers AT...

Page 22: ...HTTP port of the panel has been changed you must append the port number to the URL used to access the panel See the Password Reset section for instructions on how to reset the port number to the defa...

Page 23: ...Consult the fuse manufacturers specifications Power Consumption 2 5 watts Maximum Cable Length 100 meters Voltage Drop without fuse 60mV Typical Alarm Contact Form C Dry Contacts 1A 60VDC Max Ethernet...

Page 24: ...ials accurately describe ICT product specifications and capabilities at the time of publication However because of ongoing improvements and updating of ICT products ICT cannot guarantee the accuracy o...

Reviews: