background image

LIMITED WARRANTY

INNOVATIVE CIRCUIT TECHNOLOGY LTD.

26921 GLOUCESTER WAY     LANGLEY, BRITISH COLUMBIA, CANADA     V4W 3Y3

T

 604.856.6303     

F

 604.856.6365     

www.ict-power.com

ICT Limited Warranty is only intended for the benefit of the original 
Purchaser  of  this  product.  This  Warranty  is  not  transferable  or 
assignable  without  the  prior  written  permission  of  ICT.  ICTʼs  sole 
obligation and liability under this warranty is limited to either repairing 
or replacing defective products at the sole discretion of ICT. When 
repairing or replacing the products, ICT may use products or parts 
that are new, equivalent to new or re-conditioned. Parts repaired or 
replaced  during  the  warranty  period  will  be  under  warranty  for  the 
remainder of the warranty period.

The warranty period on ICT products purchased new from ICT is two 
years. The warranty period for a repaired product or part thereof is 
ninety (90) days or the remainder of the unexpired term of the new 
product warranty period, whichever is greater. Repair or replacement 
of a defective product or part does not extend the original warranty 
coverage period. 

No  claim  will  be  accepted  unless  written  notice  of  the  claim  is 
received  by  ICT  in  accordance  with  ICTʼs  Return  Material 
Authorization  (RMA)  procedure,  as  soon  as  reasonably  possible 
after the defect is discovered. A valid product serial number must be 
provided  with  the  RMA  claim  to  prove  eligibility.  The  RMA  form  is 
available 

on 

the 

ICT 

website 

at 

www.ict-power.com/support/warranty-repair/. 

The Purchaser shall at their own risk and cost return the defective 
product to ICTʼs factory or designated repair center once an RMA is 
issued by ICT. Return of the products to the customer after repair is 
completed shall be prepaid by ICT unless otherwise mutually agreed 
between  the  parties.  Products  shipped  to  ICT  which  have  incurred 
freight damage will not be covered by this Warranty and any repairs 
or  replacement  parts,  components  or  products  needed  will  be 
invoiced in the full current price amount and returned freight collect 
to Purchaser.  It is the Purchaserʼs responsibility to check the product 
upon  receipt  for  any  damage  during  shipping  and  to  contact  the 
carrier or shipper regarding such damage. Product that is returned 
as  defective,  which  is  determined  to  operate  within  published 
specifications will be returned to the Purchaser freight collect. 

This  Warranty  will  be  void  if  the  product  has  been  subjected  to 
misuse, neglect, accident, exposure to environmental conditions not 
conforming to the productsʼ limits of operation, improper installation 
or  maintenance,  improper  use  of  an  electrical  source,  defects 
caused by sharp items or by impact pressure, a force majeure event,  
has  been  modified  or  repaired  by  anyone  other  than  ICT  or  its 
authorized  representative,  has  been  subjected  to  unreasonable 
physical,  thermal  or  electrical  stress,  improper  maintenance,  or 
causes  external  to  the  unit  including  but  not  limited  to  general 
environmental  conditions  such  as  rust,  corrosive  atmospheres, 
sustained temperatures outside the specified operating range of the 
equipment,  exposure  to  power  surges  and/or  electrical  surges, 
improper grounding, mould or dust, animal or insect damage, water 
damage or immersion in liquid of any kind.

ICT  does  not  control  the  installation  and  use  of  any  ICT  product. 
Accordingly,  it  is  understood  this  does  not  constitute  a  warranty  of 
performance or a warranty of fitness for a particular purpose.

THE

POWER

OF

RELIABILITY

NOTES

These  converters  incorporate  a  special  noise  filter 

design.  For  proper  filtering,  the  converter  chassis  

must be grounded.

The  continuous  current  ratings  are  for  40

°

C  ambient 

temperatures.  Please  de-rate  the  output  current  rating 

2%/

°

C  for  operating  from  40

°

C  to  60

°

C  ambient 

temperatures.

4

4

Remove  the  cover  to  check  fuse  inside  the  unit.  If 

blown, replace it only with a fuse of the same rating.

Check for proper voltage at the input while converter is 

under load.

Check  for  any  erratic  voltage  conditions  at  the  input 

that might trigger the overvoltage protection.

4

4

4

TROUBLESHOOTING

Incorrect  wiring  may  damage  both  the  converter 

and any equipment connected.

Do  not  place  the  unit  on  or  near  any  sources  of 

heat and moisture.

Servicing of unit should be done only at ICT factory.

4

4

4

WARNING

ICT ISOLATED SERIES 2 CONVERTERS

SETUP

ICT ISOLATED SERIES 2 DC-DC converters feature an 

all-new design that builds on the ICT legacy of reliability 

and  performance.  This  line  delivers  higher  efficiency 

and  an  on/off  control  contact  to  help  save  energy  and 

battery life.

ISOLATED  SERIES  2  converters  can  operate  from  a 

negative  or  positive  ground  electrical  system,  and  are 

ideal  for  applications  where  complete  isolation  is 

necessary  between  primary  and  secondary  circuits,  as 

well as from the chassis.

These  instructions  should  be  read  before  using  the 

product and saved for future reference.

Mount converter securely.

Do  not  apply  power  until  the  unit  is  completely 

wired.

4
4
4

4
4

4

Default Configuration From Factory

All models are output-enabled by factory default:

> For models ICT206012-35AI2, ICT206024-20AI2, 

ICT1212-35AI2  and  ICT1224-20AI2,  a  jumper  is 

installed between the two REMOTE terminals. 

>  For  all  other  models,  a  jumper  is  installed 

between  the  REMOTE  terminal  and  the  INPUT 

POS terminal.

Remote On/Off Feature

To  use  the  remote  on/off  feature,  remove  the 

jumper.

> For models ICT206012-35AI2, ICT206024-20AI2, 

ICT1212-35AI2 and ICT1224-20AI2, short/open the 

REMOTE  CONTROL  terminals  to  turn  the  unit 

on/off. 

> For all other models apply the input voltage to the 

REMOTE terminal to enable the output.

Connect load to the output.

Connect  power  source  to  the  input  using 

appropriate fusing for the application

For  the  best  results,  wire  converter  directly  to  the 

battery using heavy gauge wire.