Option Selection 3-1
Chapter 3
Option Selection
Overview
Voltage output ranges are determined by switch settings as described in the following
paragraphs. Also, the method to update D/A outputs is programmable as described here
and in Chapter 5, Programming .
Output Ranges
There is a three-position slide switch associated with each DAC channel to make voltage
range selection: switches S1 (Channel 0) through S6 (Channel 5). A silk-screen diagram
on the card defines switch positions to use for each range. In addition to the switch, one
jumper per channel is used to select Voltage vs Current Output. The following table
presents the same information:
Table 3-1. Output Ranges
Voltage Range
S1
S2
S3
JP1-16
0 to +2.5V
OFF
OFF
On
Set in Position V
0 to +5V
OFF
OFF
OFF
0 to +10V
OFF
ON
OFF
-2.5V to +2.5V
ON
OFF
ON
-5V to +5V
ON
OFF
OFF
-10V to +10V
ON
ON
OFF
4 mA to 20 mA
OFF
OFF
OFF
Position I