background image

5.

Warranty

                      

Except as hereinafter in this Section set forth, all new apparatus sold by ICS Inc. is 
warranted for a period of one year from the date of shipment to the Buyer, to be free 
from defect in material and workmanship. If the buyer within this period gives ICS Inc. 
written notice of any alleged defect in any such apparatus and provides an opportunity 
to perform any appropriate test thereon ( the time and place to be mutually agreed 
upon and ICS Inc. at its option, to be present thereat) and if the apparatus is found not 
to be in conformity with this warranty, ICS Inc. will, at its option, and expense either 
repair   the   same   or   supply   a   replacement   therefore.   The   Buyer   will   pay   all   return 
transportation charges in connection with same.

The return of equipment to ICS Inc. must be authorized in advance by ICS Customer 
Service   personnel.     Contact   the   Service   Department   for   assignment   of   an   RMA 
(Return Material Authorization) number which must be marked on the outside of the 
shipping container. Users of equipment  returned  to ICS Inc.  which is  found to  be 
operating properly will be assessed recalibration and inspection charges as well as all 
shipping cost.

On repaired apparatus, the warranty shall  be as for new apparatus except that it shall 
only apply to the parts repaired or replaced by ICS Inc. No separate warranty shall 
apply to repaired apparatus as a whole or to  parts not repaired by ICS Inc. 

ICS Inc. reserves the right to make changes, additions and / or improvements in its 
product previously sold.

Due to nature of certain equipment installation, it could be impractical to remove ICS 
Inc.’s portion of the equipment from the customer ‘s premises to ICS Inc.’s facility. In 
such case and at the request of the Buyer, ICS Inc. will perform such services as can 
be satisfactorily rendered at the Buyer’s facility. The Buyer will be charged for travel 
and living expenses incidental to the service call.

However, no charges will be made for actual service time or any parts that may be 
required if this warranty is applicable.

The warranties of ICS Inc. on all apparatus do not cover, and ICS Inc. makes no 
warranty with respect to:

a) Failures not reported to ICS Ins. within the warranty period above specified.

b) Failure or damage due to misapplication, abuse, improper installation or abnormal 
conditions to temperature, dirt  or corrosive matter.

c) Failure due to operation, either intentional or otherwise above rated capacities or in 
an otherwise improper matter.

8

Summary of Contents for 9300057

Page 1: ...NINTERRUPTIBLE POWER SYSTEM MODEL M95 600 SERIES PART NO 9300057 DRAWING NO 8060180 ISSUED 5 21 07 REV B RELEASED INSTRUMENTATION AND CONTROL SYSTEMS INC 520 WEST INTERSTATE ROAD ADDISON ILLINOIS 6010...

Page 2: ...ny situation develops that is different from what is described herein contact the factory for further assistance 1 3 Proprietary Notice This equipment was designed and manufactured under several paten...

Page 3: ...s This UPS is provided with external batteries which must be connected to the unit Confirm that all sources of power are off and that the battery circuit breaker on the left side of the cabinet is off...

Page 4: ...in the down position to prevent further discharge of the battery 2 6 5 If servicing of the UPS or the battery is required disconnect the battery cable at the battery before performing any maintenance...

Page 5: ...LOAD PRESENT STATIC SWITCH CLOSED BATTERY CHARGER Figure 3 1 Commercial Power On 3 3 Operation From Battery During the loss of commercial AC power the battery provides DC current to the inverter which...

Page 6: ...he factory However if any adjustments need to be made it is probably due to component changes in the field over a long period of time Under those circumstances it is important that the user contact th...

Page 7: ...t when commercial power is present X No AC output when commercial power is not present X Check Battery Battery does not charge X X Check Battery Output voltage low X Reduce Load Output frequency low o...

Page 8: ...s well as all shipping cost On repaired apparatus the warranty shall be as for new apparatus except that it shall only apply to the parts repaired or replaced by ICS Inc No separate warranty shall app...

Page 9: ...ns and other consequential damages whether direct or indirect and whether or not resulting from or contributed to by the default or negligence of ICS Inc its agent employees and sub contractors which...

Page 10: ...ature 10 to 40 degrees C Operating Humidity 0 to 85 non condensing Storage Temperature 0 to 65 degrees C Input Output Connections Terminal strip with provisions for conduit entry 6 2 Controls Battery...

Page 11: ...BATTERY WIRES 8GA AWG MIN ALL OTHER WIRES 18GA AWG MIN TOTAL UPS LOAD WITH BATTERY BACKUP 5AAC MAX 2 HOURS BACKUP TIME AT 5 0 AAC OUTPUT 4 HOURS BACKUP TIME AT 2 5AAC OUTPUT CONNECT TO EARTH GROUND 11...

Page 12: ...CABINET DIMENSIONS 12...

Page 13: ...P INPUT OUTPUT CONNECTION ACCESS 4 DUAL CONCENTRIC CONDUIT HOLES OPERATING TEMPERATURE 10 40 DEGREES C OPERATING HUMIDITY 0 85 NON CONDENSING STORAGE TEMPERATURE 0 65 DEGREES C 4 CONTROLS BATTERY CIRC...

Page 14: ...ted 3 3 Turn on battery circuit breaker handle up The characteristic sound of the main transformer in the UPS may change somewhat due to charging of the battery system 3 4 Connect the load s to the UP...

Reviews: