![background image](http://html1.mh-extra.com/html/ics/890-series/890-series_operators-manual_3550594007.webp)
© 2014 ICS, Blount International Inc. Specifications are subject to change without notice. REV021414 F/N 566100
890 SERIES OPERATOR’S MANUAL
7
TECHNICAL SPECIFICATIONS
890 Series
8 gpm (30 lpm)
890 Series
12 gpm (45 lpm)
Weight w/out bar and
chain (1' hose whips)
23.5 lbs (10.6 kg)
Length
23 inches (58.5 cm)
Height
10.5 inches (26.5 cm)
Width
9.5 inches (24 cm)
Hydraulic Supply
8 gpm (30 lpm) @
2,500 psi (172.5 bar)
12 gpm (45 lpm) @
2,500 psi (172.5 bar)
Hydraulic Fluid
Requirements (Type)
Mobil DTE 13M or equivalent
Water Pressure
Minimum: 20 psi (1.5 bar)
Water Flow
1 gpm (4 lpm) minimum
Operating Speed
6,100 rpm (avg. free running)
5,500 sfm (avg. free running chain)
6,500 rpm (avg. free running)
5,800 sfm (avg. free running chain)
Noise Level
(Sound Pressure Level)
98 dB @ 3 ft (1 m)
Noise Level
(Sound Power Level)
107 dB @ 3 ft (1 m)
Vibration
2.0 m/sec
2
(Front Handle)
6.0 m/sec
2
(Rear Handle)
Torque
122 in-lbs (13.8 Nm)
170 in-lbs (19.2 Nm)
Horsepower
11.5 hp (8.6 kW)
17.5 hp (13 kW)
*Product data shown is rated based on maximum input conditions and efficiency
assumptions and may vary dependent on power supply.