IVMZ
.2
Device description
Technical changes reserved
- 5 -
Accessories:
Connection cable with moulded M12x1 coupling socket.
M12x1 coupling socket as component.
1.2 Intended use
The magnetic inductive flow sensor
IVMZ
.2 must only be used for measuring and
metering liquids with a minimum conductivity of 20
μ
S/cm.
Never use the
IVMZ
.2 as a safety
component.
The operational safety of the device supplied is only guaranteed by intended use. The speci-
fied limits (
§ 9 “Technical data”) may under no circumstances be exceeded.
Before installing the device, check that the wetted materials of the device are compatible with
the media being used (
Ensure that the measuring tube of the
IVMZ
.2 is always completely
filled
§ 4.1 “Installation instructions”).
Ensure that the conductivity of the fluid is at least 20
μS/cm.
1.3 Exclusion of liability
We accept no liability for any damage or malfunctions resulting from incorrect installation, in-
appropriate use of the device or failure to follow the instructions in this operating manual.
WARNING! No safety component!
The magnetic inductive flow sensor of the series
IVMZ
.2 is no safety component in
ac- cordance with Directive 2006/42/EC (Machine Directive).
Measuring tube empty (or partially filled). / Conductivity too low.
The green LED may blink irregularly if the measuring tube of the
IVMZ
.2 is empty or
par-tially filled or if the conductivity of the fluid being used is too low. Random pulses
will be present at the output, but they do not represent an actual flow.