IVMZ
.2
Technical data
Technical changes reserved
- 17 -
Type
I
VMZ03
I
VMZ06
I
VMZ08
I
VMZ15
I
VMZ20
I
VMZ25
Process variables
Medium to measure
Water and other conductive liquids
- Conductivity
> 20
μ
S/cm
- Temperature
(PVDF measuring tube)
- Temperature
(POM measuring tube)
-15…80 °C (non-freezing)
-15…60 °C (non-freezing)
Ambient temperature
-15…60 °C
Storage temperature
-15…60 °C
Nominal diameter
DN 3
DN 6
DN 8
DN 15
DN 20
DN 25
Inner diameter
3 mm
8 x 2 mm
8 mm
14 mm
18 mm
25 mm
Max. working pressure
(at … °C)
10 bar (20 °C) • 8 bar (40 °C) • 6 bar (60 °C) • 5 bar (80 °C)
Process connection
- male thread
G
⅜
B
G½ B
G½ B
G¾ B
G1 B
G1¼ B
9.2 Materials table
Component
Material
Component-
wetted
Housing
ABS
Measuring tube
POM or PVDF (option)
X
Process connections
POM or PVDF (option)
X
O-ring
EPDM or FKM (option)
X
Electrodes and earthing rings
Stainless steel 1.4404 or Hastelloy C®
X