NAV6 Series NAVTEX System User Guide
30
Barometer Settings
(NAV6plus and NAV6repeater only)
The Time zone offset may be used to adjust the
barometer time axis to show local time.
The Forecast section is used to set the sensor
location, weather warning alarm and warning
threshold. Use the up and down keys to select the
setting you wish to change and use the
and
Softkeys 2 and 3 to change the setting.
The Calibration section is used to set the altitude and
air pressure. Use the up and down keys to select the
setting you wish to change and use the
and
Softkeys 2 and 3 to change the setting.
Option
Setting
Notes
Time zone offset
HH:MM
Adjusts the time axis offset in 15 minute steps.
Sensor Location
Sea
Land
Adjusts the wind forecast for use over land or at sea.
Weather Warning
Alarm
Off
Timed
Repeat
Sets the air pressure alarm (two beeps repeated at a 5 second interval)
operating mode when the rate of pressure change exceeds the warning
threshold.
Sounds the air pressure alarm 5 times or until cancelled by a key press.
Repeats the air pressure alarm until cancelled by a key press.
Warning
threshold
Auto
XX.X
Set the pressure rate of change threshold that will trigger the audible alarm.
A setting of Auto means ≥1 hPa/h
Altitude
-1000-5000
Sets the altitude offset in metres for use when the receiver is used ashore.
Air pressure (at
sea level)
XXXX.X
Sets the reference air pressure at sea level.