Physical
Size 7.45" L x 5.57" W x 1.52" H
(18.92 cm L x 14.15 cm W x 3.86 cm H)
Weight
1.6 lbs. (0.73 kg.)
plus power adapter
Construction
RoHS Compliant
Temperature
Operating
-10 °C to +65 °C
Storage
-40 °C to + 70 °C
Humidity
0-90% RH non-condensing
Shock/Vibration Normal handling
Connectors
GPIB
GPIB 24 pin ribbon
with metric studs.
Ethernet
RJ-45
Power
9 to 32 Vdc @ 4 VA
RFI/EMI
CE Certifi ed
EEC Standards EN 61000-6-4:2001,
EN 61000-6-2:2001,
EN 55024:1998,
and EN 55022:1998.
Included Accessories
Instruction Manual
CD-ROM with support information.
LAN Crossover Cable.
UL/CSA/VDE approved AC power Adapters
provided for:
US - 115±10% Vac, 60 Hz (std.)
-U Universal - 115/230±10% Vac, 50/60 Hz
with UK, Europe, Australia (China) and
US plugs
4865 SPECIFICATIONS
Ethernet - GPIB Controller with 115 VAC adapter, Manual and CD-ROM
4865
Ethernet - GPIB Controller with 115/230 VAC adapter with universal plug set, Manual and CD-ROM
4865-U
GPIB Accessary Cables
See separate data sheet
Rack Mounting Kits (holds one or two 4865s). See separate data sheet
Single - 114210, Dual - 114211
ORDERING INFORMATION
Part Number
Copyright 2012 ICS Electronics, Specifi cations subject to change without notice
Supported Standards
IEEE 488.1 Capabilities:
The 488-USB meets IEEE-STD-488.1 with the
following capabilities:
AH1, SH1, T6, L4, SR1, RL2, PP0, DC1,
DT1, C0 and E2
E2 Drivers incorporate power up/down
protection.
4865 Address 0 to 30 [0]
488 Bus Performance
Long term GPIB transfer rates are limited by
the LAN data transfer rate, the Client-computer
performance, the GPIB controller and the LAN
instrument or device. Internal delays vary with
the amount of data transferred and 4865's activity
when the message was received.
Short term transfer rates:
GPIB to 4865 >20 kbyte/s
4865 to GPIB >18 kbytes/s
Internal delays:
*IDN? query
46 ms typical
*CLS command 18 ms typical
Supported GPIB (IEEE-488.1) Commands
Converted to the equivalent VXI-11 rpc.
Device Clear
Device Trigger
Local
Remote
Serial Poll
VXI-11 Capabilities
Fully VXI-11.3 compliant
VXI-11.3
Client side
Channel types Data
Instrument links 64 max
Locking
By instrument link
RPC Protocol
Conforms to ONC RPC Version 2
Ethernet Interface
Type
IEEE 802.3 compliant
Speeds
10BaseT (10 Mb/s)
100BaseT (100 Mb/s)
IP Address
Static or DHCP (AutoIP)
Factory setting DHCP with default to
169.254.48.65 if no DHCP
server found.
Net Mask
255.255.0.0
Interface name inst0
11/12
The VXI-11 Specifi cation is available from the VXI Consortium at http://www.vxibus.org/specs.html or from ICS's website
at http://www.icselect.com/vxi_spec.html
Companion Instrument
The 4865 supports single instrument that is VXI-
11.3 and IEEE-488.2 compatible.
System Requirements
Computer with an IEEE-488.2 GPIB Controller.
Device messages must be terminated with the
IEEE-488.2 new line terminator (linefeed with
EOI asserted) or with just EOI asserted if the LAN
instrument does not require a terminator.
Computer with an IEEE 802.3 LAN interface and
a web browser for confi guring the 4865.
Internal WebServer
The internal WebServer provides HTML web
pages for viewing and setting the 4865's network
settings.
Controls and Indicators
CONTROLS
Power
Front-panel switch
LAN Reset
Rear-panel push-button
LEDs
PWR
Power on
LAN
Unit connected to an active
network or network device.
ACT
Transferring messages to/
from the network.
RDY
Blinks when looking for an
instrument. Steady on when
linked to an instrument
TALK
4865 is addressed to talk
LSTN
4865 is addressed to listen
SRQ
4865 asserting SRQ on the
GPIB bus.
ERR