background image

USB Rover 200 

2

About the USB Rover 

The USB Rover breaks the five-meter distance barrier for the connection of 
USB devices and allows users to enjoy the benefits of USB technology 
beyond the desktop. With the USB Rover, USB devices can be located up to 
40 meters from the host computer. In addition, the USB Rover provides 
electrical isolation between the host and the device.  

The USB Rover is composed of two individual units, the LEX unit and the 
REX unit connected by a custom length of fiber cable. 

The LEX unit 

The LEX unit connects to the host computer through a captive USB Type A 
connector. The LEX unit is powered by the host over USB. 

The REX unit 

The REX unit connects to the USB device through a USB Type A 
receptacle. An external AC adapter provides power to the unit and to any 
USB device that may be connected. The REX unit of the USB Rover 200 
enables you to connect one full-speed or low-speed USB device.  

USB Cables 

USB cables have two distinct connectors. The Type A connector is used to 
connect the cable from a USB device to the Type A port on a computer or 
hub. The Type B connector is used to attach the USB cable to a USB device. 

USB Type A 

port 

USB Type A 

connector 

USB Type B 

port 

USB Type B 

connector 

Compatibility 

The USB Rover complies with USB 1.1 specifications governing the design 
of full-speed and low-speed USB devices. However, Icron Technologies 
Corporation does not guarantee that all USB 1.1 devices are compatible with 
the USB Rover. 

Summary of Contents for USB Rover 200

Page 1: ...USB Rover 200 User Guide Extending the Range of USB Icron by scanmagnetics oy www scanmagnetics com ...

Page 2: ...t the interference by one or more of the following measures x Reorient or relocate the receiving antenna x Increase the separation between the equipment and receiver x Connect the equipment into an outlet on a circuit different from that to which the receiver is connected x Consult the dealer or an experienced radio TV technician for help CE Statement We Icron Technologies Corporation declare unde...

Page 3: ...ou Begin 3 Installing the LEX unit 3 Installing the REX unit 3 Completing the Installation 3 Connecting a USB Device 3 Troubleshooting 4 Specifications 5 Limited Hardware Warranty 6 Hardware Remedies 6 Limitation of Liability 6 Obtaining Warranty Service 7 Contacting Technical Support 7 ...

Page 4: ...USB Rover 200 ii Notes ...

Page 5: ...of USB devices NOTE Notes give additional information that could make installation easier Product Contents When you open your product for the first time you should find the following items x USB Rover 200 User Guide x LEX unit and REX unit with integral cable x AC power adapter To complete the installation you will also require the following items that are not included with the product x USB compa...

Page 6: ...over USB The REX unit The REX unit connects to the USB device through a USB Type A receptacle An external AC adapter provides power to the unit and to any USB device that may be connected The REX unit of the USB Rover 200 enables you to connect one full speed or low speed USB device USB Cables USB cables have two distinct connectors The Type A connector is used to connect the cable from a USB devi...

Page 7: ...it near the USB device 2 Plug the AC adapter into an available AC outlet Connect the DC power cord to the REX unit Completing the Installation 1 Switch on the computer and check that the AC adapter is powered on 2 Depending on the operating system you are using open the Device Manager dialog box 3 Expand the entry labeled Universal Serial Bus Controllers 4 In the expanded entries you should find o...

Page 8: ...e is not connected to the REX unit b The USB device is malfunctioning c The computer does not recognise the USB device d The computer does not support USB hubs e The USB Rover is malfunctioning 1 Check that the USB device is securely connected to the USB port on the REX unit 2 Disconnect the LEX unit from the computer 3 Connect the USB device directly to the USB port on the computer 4 If the devic...

Page 9: ...ies with the USB Rover 200 The maximum number of such hubs is 10 meter cables 4 hubs 20 meter cables 3 hubs 30 meter cables 2 hubs 40 meter cables 1 hub Maximum power available to USB at REX unit 500 mA LEX unit connector upstream 1 x USB Type A REX unit connector downstream 1 x USB Type A LEX unit dimensions 87 mm x 30 mm x 16 mm 3 45 x 1 2 x 0 65 REX unit dimensions 80 mm x 30 mm x 16 mm 3 15 x ...

Page 10: ...nd fitness for a particular purpose and non infringement of third party rights with respect to the hardware Icron Technologies Corporation dealer agent or employee is authorized to make any modification extension or addition to this warranty Under no circumstances will Icron Technologies Corporation its suppliers or licensors be liable for any costs of procurement or substitute products or service...

Page 11: ...will be shipped to you at Icron Technologies Corporation s expense not later than thirty days after Icron Technologies Corporation receives the defective product Address the returned product to RMA Coordinator Scanmagnetics oy PL 34 00811 Helsinki Tel 09 2712200 Contacting Technical Support If you require technical assistance send an e mail message to techsupport icron com To help us serve you bet...

Page 12: ...0 00138 A01 Icron Technologies Corporation 4664 Lougheed Highway Suite 275 Burnaby BC V5C 5T5 Canada Icron by scanmagnetics oy T 09 2712200 F 09 2712210 eml icron scanmagnetics com www scanmagnetics com ...

Reviews: