Icron USB 2.0 Ranger Series User Manual Download Page 12

USB 2.0 Ranger 140 and USB 2.0 Ranger 440 

a straight-through conductor configuration with no crossovers, and 
must be terminated with 8-conductor RJ45 connectors at both ends.  

With Surface Cabling 

1.  Plug one end of the Category 5 UTP cabling (not included) into the 

Link port on the LEX unit. 

2.  Plug the other end of the Category 5 UTP cabling into the Link port 

on the REX unit. 

With Premise Cabling 

1.  Plug one end of a Category 5 patch cord (not included) into the 

Link port on the LEX unit. 

2.  Plug the other end of the patch cord into the Category 5 information 

outlet near the host computer. 

3.  Plug one end of the second Category 5 patch cord (not included) 

into the Link port on the REX unit. 

4.  Plug the other end of the second patch cord into the Category 5 

information outlet near the USB device. 

 NOTE

: The maximum length of the Category 5 UTP cable must not exceed 

50 meters. Cat-5 patch cords must not exceed 10m 

Checking the Installation 

1.  Check that the Power LEDs on the LEX unit and REX unit are both 

on. 

2.  Check that the Link LEDs on the LEX unit and REX unit are both 

on. 

3.  Check that the Host LED on the LEX unit is on. 

4.  On the host PC, open the Device Manager applet. Expand the entry 

for Universal Serial Bus controllers by clicking the + sign. If the 
USB 2.0 Ranger has been installed correctly you should find it 
listed as a Generic USB Hub. 

Connecting a USB Device 

1.  Install any software required to operate the USB device(s). Refer to 

the documentation for the device(s), as required. 

2.  Connect the USB device to the Device port on the REX unit. 

Summary of Contents for USB 2.0 Ranger Series

Page 1: ...USB 2 0 Ranger 140 and USB 2 0 Ranger 440 User Guide USB 2 0 Ranger 440 Model Shown powered by ExtremeUSB...

Page 2: ...on of the USB 2 0 Ranger 140 or 440 in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Statement We...

Page 3: ...n 7 Installing the LEX unit 7 Installing the REX unit 7 Connecting the LEX unit to the REX unit 7 Checking the Installation 8 Connecting a USB Device 8 Troubleshooting 10 Specifications 12 Limited Har...

Page 4: ...USB 2 0 Ranger 140 and USB 2 0 Ranger 440 Notes ii...

Page 5: ...e Local EXtender LEX unit Remote EXtender REX unit AC power adapter 2 USB cable 2m long To complete the installation you will also require the following items that are not included with the product US...

Page 6: ...dapters supplied with the USB 2 0 Ranger The DC supply voltage used on the Ranger 140 or Ranger 440 units is NOT the same as Icron Technologies USB 1 1 Ranger products Use of substitute adapters may c...

Page 7: ...vices can be located up to 50 meters from the host computer The USB 2 0 Ranger is composed of two individual units the LEX unit and the REX unit The LEX unit USB 2 0 Ranger 140 and USB 2 0 Ranger 440...

Page 8: ...nection to the USB device is via a conventional USB cable Additional devices may be connected through attachment of a USB Hub at the REX unit The REX unit is required to be connected to a power outlet...

Page 9: ...he USB device is via a conventional USB cable Additional devices may be connected through attachment of a USB Hub at the REX unit The REX unit is required to be connected to a power outlet through an...

Page 10: ...g is the standard data communications cable installed in most commercial and some residential buildings USB Cables USB cables have two distinct connectors The Type A connector is used to connect the c...

Page 11: ...e with the Ranger 140 and Ranger 440 requirements 3 Connect the power adapter to the LEX unit 4 Plug the Type B connector on the USB cable included into the Host port on the LEX unit 5 Plug the Type A...

Page 12: ...n the REX unit 4 Plug the other end of the second patch cord into the Category 5 information outlet near the USB device NOTE The maximum length of the Category 5 UTP cable must not exceed 50 meters Ca...

Page 13: ...User Guide 3 Check that the Device LED on the REX unit is on 9...

Page 14: ...unit and REX unit 1 Ensure that a Category 5 UTP cable with straight through conductors is connected between the LEX unit and REX unit 2 Connect a short Category 5 patch cord between the LEX unit and...

Page 15: ...y the first device may not be compatible with the USB 2 0 Ranger Contact technical support for assistance All LEDs on both the LEX unit and REX unit are on but the device does not operate correctly Ca...

Page 16: ...mpatible with the Ranger 2 0 systems Power available to USB device at REX unit Ranger 140 1 x 500 mA Ranger 440 4 x 500 mA USB cable 2 meters 6 6 ft LEX unit connector upstream 1 x USB Type B LEX unit...

Page 17: ...Ranger 140 1 27kg 2 8 lbs Ranger 140i NA 1 72kg 3 8 lbs Ranger 140i EU 1 81kg 4 0 lbs Ranger 440 1 27kg 2 8 lbs Ranger 440i NA 1 72kg 3 8 lbs Ranger 440i EU 1 81kg 4 0 lbs Temperature range 4 C to 40...

Page 18: ...ntability and fitness for a particular purpose and non infringement of third party rights with respect to the hardware Icron Technologies Corporation dealer agent or employee is authorized to make any...

Page 19: ...u at Icron Technologies Corporation s expense not later than thirty days after Icron Technologies Corporation receives the defective product Address the returned product to RMA Coordinator Icron Techn...

Page 20: ...Icron Technologies Corporation 4664 Lougheed Highway Suite 275 Burnaby BC V5C 5T5 Canada Tel 604 638 3920 Fax 604 638 3930 www icron com 90 00249 A01...

Reviews: