Summary of Contents for PH55 Series

Page 1: ...2 3 SAFEINSTALLATIONREQUIREMENTS 2 4 LOCATING THE UNIT 2 5 UNITELECTRICALWIRING 4 6 WIRINGDIAGRAMS 8 7 ELECTRICNEATINSTALLATION GENERALINFORMATION 10 8 INSTALLINGELECTRICHEATACESSORY 10 9 HEATERELECTR...

Page 2: ...e and size NOTE It is the personal responsibility and obligation of the customer to contact a qualified installer to ensure that the installation is adequate and conforms to governing codes and ordina...

Page 3: ...g The platform may be made of either concrete or pressure treated wood and MUST be level and strong enough to support the unit s weight Position platform separate from the building s foundation Instal...

Page 4: ...ting plate for the ground connection Use a copper conductor of the appropri ate size from the unit to a grounded connection in the electrical service panel or to a properly driven and electrically gro...

Page 5: ...the unit and other devices or be tween separate devices which are field installed and located MUST NOT exceed the temperature limitations for type T wire and MUST be installed according to the manufa...

Page 6: ..._ y R C R RV I I I I I L _ J I O Y W I I Lw _ w DEFROST HEAT I I L y y COMPRESSOR L O e O HEAT COOL BL e C COMMON R e R 24 VAC G FAN I I I G tF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE...

Page 7: ...RANSFORMER COMPR COMPRESSOR CAP CAPACITOR CONT CONTACTOR JPR JUMPER WIRE FAN DEFROST CONTROLDFs _ _ LOC OR_ I I JPR _i ZZZZ _ E F R _ i I f O Y W mv _U I_ I L_ e W DEFROST HEAT I j I e Y COMPRESSOR L...

Page 8: ...I I I I I I I I I I I R C O Y W I I J B GND LUG I I I I I I I I I I I I I I I I I I I I I BK I I y _ I I I I I I I I I I I I R RV I I Lw W DEFROSTHEAT L y Y COMPRESSOR I L O O HEAT COOL I I BL C COMMO...

Page 9: ...CONTROLDFs _ F R _R If O Y W RV _1_ jq _2P2_ ZZZZ _ I I e W DEFROST HEAT I I _ Y COMPRESSOR L e O HEAT COOL C COMMON e 4_ R 24 VAC G FAN _ LEGEND GND GROUND LOC_ LOSS OF CHARGE PRESSURE SWITCH DFS DE...

Page 10: ...GURE 7 The Electric Heat Accessory Breaker Electrical shock hazard Shut OFF electric power at unit disconnect and or service panel before beginning the following procedures Failure to follow this warn...

Page 11: ...t Model Number Anticipator Setting AMMK05AHB A 18 AM MK07AH B A 36 AMMK10AH B A 36 AMMK15AH B A 36 AM MK20AH B A 54 Limit Controls The limit controls are mounted on the face of the heater and are wire...

Page 12: ...d wire with terminal in the heater wire harness to the loose red wire from the unit sequencer 7 Connect the white wire from the heater wire harness to the white wire from the thermostat at the field s...

Page 13: ...5AHB AMMK07AHA AMMK07AHB AMMK10AHA AMMK10AHB AMMK15AHB AMMK20AHB Accessory Electric Heater Heating Data Use With 2 5 TON 2 5 TON 2 5 TON 21 2 5 TON 21 2 5 TON Supply Voltage 240 1 60 208 1 60 240 1 60...

Page 14: ...GY ORANGE 0 RED R VIOLET V WHITE W YELLOW y NOTES 1 ALL WIRING MUST BE DONE IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES 2 WIRING THAT IS CIRCLED MUST BE DONE BY INSTALLER 3 IF ANY WIRE MUS...

Page 15: ...ROPRIATE SEALS ARE IN PLACE SEE FIGURE 12 Ductwork Connections The use of flexible non combustible connectors between main trunk ducts and supply and return air plenums is recommended to minimize vibr...

Page 16: ...ATA ON THE UNITS TECHNICAL DATA LABEL LOCATED ON THE UNIT NOTE On Heat Pumps Electric heater blower wire must be attached to the same speed tap required for cooling heat pump operation See FIG URE 11...

Page 17: ...Turn electric power OFF Auxiliary Heating NOTE Repeat circulating air blower procedure above if Auxiliary Electric Heat is being installed after unit has been installed and checked out Temperature Ri...

Page 18: ...ng The delay can be by passed by jum pering the test pins on the defrost control board this reduces the delay from 30 minutes to 7 seconds from 60 minutes to 14 seconds and from 90 minutes to 21 secon...

Page 19: ...arranty DOES NOT COVER any labor material refractory chambers oii nozzles refrigerant refrigerant inspection and refrigerant reclaiming freight and or handling charges associated with any repair or re...

Page 20: ...C4 KAC0 TCA0 TCA2 TCA4 HHP0 HHP2 HHP4 CliP0 CliP2 CliP4 TCH0 TCH2 TCH4 PGME PYMC PHAD PGAD PA95 PAPC PAK APK Tothe original purchaser a replacement for 10 years from original date of installation only...