Summary of Contents for NDN6/GDE Series

Page 1: ...des In the United States follow all safety codes including the current edition National Fuel Gas Code NFGC NFPA No 54 ANSIZ223 1 In Canada refer tothe current edition of the National Standard Canada C...

Page 2: ...ato ries or International Approval Services installed and maintained in the building or dwelling see Note below B There can be numerous sources of fire or smoke in a build ing or dwelling Fire or smok...

Page 3: ...er damaging chemicals Refer to Combustion Ventilation Air sec tion Contaminated Combustion Air Upflow Dimensions and Clearances NTC6 GNE NTN6 NNE I K HI K I I I I C t50 060 BTU ONLY AirBaffle DO NOTRE...

Page 4: ...ed at least 18 457mm above the floor 2 This furnace is NOT to be used for temporary heat of build ings or structures under construction Install the vent pipes as short as practical See Gas Vent Instal...

Page 5: ...n right side of furnace fac ing down the pressure switch MUST be relocated to the left side of the furnace using the holes provided in the top panel Position the pressure switch in the same orientatio...

Page 6: ...directly to outside 3 When screens are used to cover openings the openings MUST be no smaller than 1 4 Cmm mesh 4 The minimum dimension of rectangular air ducts MUST NOT be less than 3 75mm 5 When si...

Page 7: ...ors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines etc VentilationAir Some provincial codes and local municipalities require ventilation or make...

Page 8: ...ted States National Fuel Gas Code venting tables Use the United States National Fuel Gas Code or NFGC Tables to size the chimney or vent Dedicated venting of one fan as sisted furnace into any masonry...

Page 9: ...C6 GNE NTN6 NNE furnaces in a horizontal left hand application you will need to mount the pressure switch to the side of the cabinet 4 NTC6 GNE NTN6 NNE series furnaces Detach pres sure switch from to...

Page 10: ...s equipped with the correct main burner orifices Refer to Table 3 for correct orifice size for a given heating value and specific gravity for natural and propane gas Note that this chart is ONLY for d...

Page 11: ...TH DIFFERENT SPECIFIC GRAVITY CONSULT THE LATEST EDITION OF THE NATIONAL FUEL GAS CODE ANSI Z223 1 and CAN B149 _ nanging Orifices Manifold Downflow 1 After disconnecting power and gas supply to the f...

Page 12: ...sed inside the furnace Failure to properly install metal gas connector can result in death bodily injury and or property damage Additional LP PipingRequirements Have a licensed LP gas dealer make all...

Page 13: ...ing in accordance with manufacturer s instructions Humidifier ElectronicAir Cleaner The furnace is wired for humidifier and or electronic air cleaner connection Electrical Connections Upflow horizonta...

Page 14: ...rs are recommended in all branches or in individual ducts to balance system s air flow If air return grille is located close to the fan inlet install at least one 90 air turn between fan and inlet gri...

Page 15: ...4 412 181 4 464 217 8 556 Opening In Base For Plenum P R 15 131 2 15 171 8 15 193 4 15 131 2 15 171 8 15 193 4 131 2 343 15 381 171 8 435 193 4 502 Typical Plenum Dimensions S T 15 131 2 15 171 8 15...

Page 16: ...rnace is provided with high velocity type filter s The size quantity and type of filter supplied with the furnace will handle the airflow required if central air conditioning is used with the furnace...

Page 17: ...nd pilot flames See Figure 23 Check for the following Figure 23 Fire or explosion hazard Turn OFF gas at shut off before connecting ma nometer Failure to turn OFF gas at shut off before con Stable and...

Page 18: ...or both heating and cooling remove the undesired motor speed lead from the Heat or Cool terminal and connect that lead to the open terminal at Unused Motor Lead location or tape off Attach a jumper be...