428 01 9700 03
3
4 3/16
11/16
L
A
B
J
K
N
P
E
FD
C
7 1/2
2 1/2
1
8
4 1/2
1 7/16
UNIT
SERIES
ABC
DE
FG
H
J
K
L
MNP
OPERATING
WEIGHT(lbs)
HC4H318
A
XOOO
2
5
6 5/8
11 1/4
5/8
2 15/16
6
167
183
42 9/10
X 18
X 28 1/10
HC4H324
A
XOOO
3
1
14
6 3/4
11 5/8
5/8
2 15/16
6
176
194
42 9/10
X 18
X 34 1/10
HC4H330
A
XOOO
3
7
11/16
8 1/8
15 7/8
3/4
3 7/16
6 1/2
187
210
50 1/2
X 20 1/2
X 40 2/10
HC4H336
A
XOXX
3
7
13 11/16
8 1/8
15 7/8
3/4
3 7/16
6 1/2
232
255
50 1/2
X 20 1/2
X 40 2/10
HC4H348
A
XOXX
4
3
14 1/2
8 1/2
18 7/8
7/8
3 7/16
6 1/2
278
303
50 1/2
X 20 1/2
X 46 2/10
HC4H360
A
XOXX
4
3
14 1/2
8 1/2
18 7/8
7/8
3 7/16
6 1/2
306
331
50 1/2
X 20 1/2
X 46 2/10
UNIT SIZE
DIMENSIONS
208
−
230
−
1
−
60
230
−
1
−
60
208/230
−
3
−
60
460
−
3
−
60
1 1/2
FIELD CONTROL SUPPLY
WIRE ENTRY
7/8
HOLE W/GROMMET
1. REQUIRED CLEARANCES: WITH COIL FACING WALL; ALLOW 6
MIN
CLEARANCE ON COIL SIDE AND COIL END AND 36
MIN CLEARANCE
ON COMPRESSOR END AND FAN SIDE. WITH FAN FACING WALL; ALLOW 8
MIN
CLEARANCE ON FAN SIDE AND COIL END AND 36
MIN CLEARANCE
ON COMPRESSOR END AND COIL SIDE. WITH MULTI UNIT APPLICATION;
ARRANGE UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOTHER.
2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING
MODE IS 55
$
F, MAX. 125
$F.
3. SERIES DESIGNATION IS THE 10TH POSITION OF THE
UNIT MODEL NUMBER.
4. CENTER OF GRAVITY
5. ALL DIMENSIONS ARE IN
INCHES
UNLESS NOTED.
FIELD POWER SUPPLY CONN.
HOLE SIZES PROVIDED:
7/8
−
1/2
TRADE
1 3/16
−
3/4
TRADE
1 3/8
−
1
TRADE
MEASUREMENT
−
ENGLISH
X = YES
O = NO
FEMALE SWEAT CONN.
VAPOR LINE CONN.
M
JUNCTION BOX FOR
POWER SUPLLY AND
CONTROL CONNECTIONS
AIR
AIR
Figure 3
-
HC4A3 Unit Dimensions