background image

 

ICP

 

DAS,

 

ZT

2000

 

DIO

 

SERIES

 

Quick

 

Start,

 

Version

 

1.2.1

   

Page

 

1

 

Copyright

 

©

 

2013

 

by

 

ICP

 

DAS

 

Co.,

 

Ltd.

 

All

 

Rights

 

Reserved.

 

ZT

2000

 

DIO

 

SERIES

 

Quick

 

Start

 

1

 

What’s

 

in

 

the

 

Shipping

 

Package?

 

The shipping package contains the following items: 

 

 

 

2

 

Preparing

 

the

 

Device

 

1.

 

Refer the chapter 3. to configure the DIP switch of ZT-2000 I/O device. 

2.

 

Install the ZT Configuration Utility to configure the ZT-2000 coordinator. 
CD: 

\

Napdos

\

ZigBee

\

ZT_Series

\

Utility 

 

http://ftp.icpdas.com/pub/cd/usbcd/napdos/zigbee/zt_series/utility

 

3.

 

Power Supply: +10 ~ +30 V

DC

 

 

ANT

124

05

 

Quick

 

Start

 

ZT

2000

 

DIO

 

Device

 

+Vs GND 

+Vs 

GND 

If any of these items are missing or damaged, please contact your local distributor 
for more information. Save the shipping materials and cartons in case you need to 
ship the module in the future. 

Summary of Contents for ZT-2053

Page 1: ...he DIP switch of ZT 2000 I O device 2 Install the ZT Configuration Utility to configure the ZT 2000 coordinator CD Napdos ZigBee ZT_Series Utility http ftp icpdas com pub cd usbcd napdos zigbee zt_ser...

Page 2: ...e value as other modules on the same ZigBee network Channel 0x00 0x01 0x0F Frequency MHz 2405 2410 2480 RF channels 0x04 0x09 0x0E or 0x0F are recommended because they do not overlap with the Wi Fi fr...

Page 3: ...ng the external rotary switch and the DIP switches The ZT 2000 device should only be rebooted once the configuration is complete DIP Switch to the ZT 2042 ZT 2043 ZT 2053 ZT 2055 DIP Switch to the ZT...

Page 4: ...ress of hardware switch is set to 0x00 it mens the address is using software configurations Refer the more detailed information at Sec 6 6 of user manual DIP Switch Number Item Status Explain OFF Vali...

Page 5: ...n of the ZigBee coordinator has been completed Set the Pan ID and the RF Channel values for the ZT 2000 I O device to the same values as the network and then reboot the device The module will automati...

Page 6: ...ZT 2570 Configurations of ZT 2000 I O Device 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 ON Number Item Status Explain 1 Address MSB OFF Address Node ID is 01 Rotation Switch 1 2 Protocol ON Use Modbu...

Page 7: ...the device settings and ZigBee I O functions The DCON Utility can be dowmload from http ftp icpdas com pub cd 8000cd napdos driver dcon_utility mulate I O channel operating via using DCON Utility Si 1...

Page 8: ...55x as a file b After clicking the Save Log icon enter the File Name and the File Path in the Windows Save dialog box Once the configuration has been successfully saved the following message will be d...