Starting

 

the

 

ZT

2000

 

I/O

 

Device

 

As  the  ZigBee  network  is  controlled  by  the  ZigBee  Coordinator,  the 

ZT-2550/ZT-2570 (ZigBee Coordinator) must be configured first. Refers to the 

documents shown below for full details of how to configure these devices. 

Once configuration of the ZigBee Coordinator has been completed, set the “Pan 

ID” and “RF Channel”values for the ZT-2000 I/O device to the same values as 

the network and then reboot the device.The module will automatically start to 

function on the ZigBee network using the default protocol. 

 

※ 

Documents 

 

http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-255x/

 

http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-257x/

 

 

※ 

Configuration  Utility

 

(Used  to  configure  the  ZT-2000  I/O  device 

Coordinator) 

 

http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/utility/

 

Summary of Contents for ZT-2024

Page 1: ...tion Utility on your Host PC to configure the ZT 2000 coordinator The utility can be founded on the CD in the Napdos ZigBee ZT_Series Utility folder or downloaded from http ftp icpdas com pub cd usbcd...

Page 2: ...other modules on the same ZigBee network ZB Channel 0x00 0x01 0x0F Frequency MHz 2405 2410 2480 ZB channels 0x04 0x09 0x0E or 0x0F are recommended because they do not overlap with Wi Fi frequency band...

Page 3: ...4 5 6 7 8 9 10 11 12 Address LSB Node ID Address MSB Node ID Protocol Checksum ZB PID ZB Channel Type Code ON Data Format Rotary Switch 0 Software Config 1 2 3 F Note Address Note 1 01 02 03 0F Node I...

Page 4: ...10 to 0x1F OFF DCON Protocol 2 Protocol ON Modbus RTU Protocol OFF Disabled DCON Protocol 3 Checksum ON Enabled DCON Protocol OFF ZigBee Pan ID 0x0000 4 ZB PID ON ZigBee Pan ID 0x0001 OFF 5 ON 0x08 OF...

Page 5: ...the ZigBee Coordinator has been completed set the Pan ID and RF Channel values for the ZT 2000 I O device to the same values as the network and then reboot the device The module will automatically sta...

Page 6: ...1 2 3 4 5 6 7 8 9 10 11 12 Number Item Status Description 1 Address MSB OFF Address Node ID is 01 Rorary Switch 1 2 Protocol ON Use Modbus RTU Protocol 3 Checksum OFF Disabled 4 ZB PID OFF Pan ID 0x00...

Page 7: ...ings and ZigBee I O functions The DCON Utility can be downloaded from http ftp icpdas com pub cd 8000cd napdos driver dcon_utility mulating I O channel operation via the DCON Utility Si 1 Launch the D...

Page 8: ...ositions A copy of the configuration file for the ZT 2000 coordinator This file can be obtained using the procedure outlined below and should be attached to your email a Set the DIP switch of the ZT 2...

Reviews: