LED indicators

 

 

LED 

Description 

EXT (red) 

on 

The external Power is active 

off 

The external Power is not active 

3G (green) 

Blinking*2 
(2 sec) 

3G module normal (After modem registered) 
Use 3G SIM card 

Blinking*1 
(2 sec) 

3G module normal (After modem registered) 

Use 2G SIM card 

off  

Modem fail (or Blinking(not 3 sec)) 

STA (orange) 

 

Normal 

3G Fail 

PIN code is wrong 

EXT on 

Blanking (1 sec) 

Always on or off 

Blinking per 50 ms 

EXT off 

Off (sleep mode) or 

Blanking (1 sec)(wake up) 

Always on 

Blanking per 50 ms 

 

 

Installation 

If  users  want  to  start  SMS-530  normally,  it  needs  to  follow  these  steps  to  install  the  SMS-530 

below: 

1.

 

Install the antenna 

2.

 

Plug in the normal SIM card (Before apply the SIM card, confirm it is OK by mobile 
phone.) 

3.

 

Pin08 and Pin09 connect to the DC.+VS and DC.GND of the power supply. 

4.

 

Follow the User’s Manual section 2.4 to wire the I/O connection. 

5.

 

If  you  want  to  use  the  backup  power,  please  connect  the  Li-battery(Option)  to  SMS-
530. 

6.

 

It is needed 30 ~ 50 seconds for SMS-530 to search the 3G base and register to the ISP. 
After finishing the process, SMS-530 would be in normal operation mode and the STA 
LED would blank (1 sec). The start time of SMS-530 depends on the strength of signal. 

 

Summary of Contents for SMS-530

Page 1: ...amaged contact the local distributors for more information Save the shipping materials and cartons in case you want to ship in the future Appearance and pin assignments DI DO Terminal No Pin Assignmen...

Page 2: ...SMS 530 Quick Start v1 0 2013 04 2 8 I O Connection DI hardware connection NC Normal Close mode NO Normal Open mode DO hardware connection...

Page 3: ...per 50 ms Installation If users want to start SMS 530 normally it needs to follow these steps to install the SMS 530 below 1 Install the antenna 2 Plug in the normal SIM card Before apply the SIM card...

Page 4: ...ally When the external power is removed from SMS 530 the power supplying to SMS 530 is from Li Battery If the voltage of Li Battery is lower than the preset limit SMS 530 can send the SMS message to i...

Page 5: ...king in SMS 530 STA LED Description Blanking per 1 sec Normal mode Blanking per 50 ms The pin code is wrong The login windows would show the field to input pin or PUK code 2 Confirm the RS232 connecti...

Page 6: ...rameters window from the specific par file 5 Version Including the firmware and Utility version information 6 System Provide users to recovery SMS 530 to factory and reset SMS 530 7 Exit To exit GT 53...

Page 7: ...ne Send data to COM3 of SMS 530 by SMS command It is possible to use SMS to send data to com port of SMS 530 The command header is The first setting phone number just has the authority to use this fun...

Page 8: ...2 Check the counter signal is at 5 40Hz 3 Check the DI mode setting Must be counter mode 6 The content of received SMS is abnormal Please select the correct language to set the content of SMS in util...

Reviews: