3.2. Voltage Input  

1.

 

PM-311x series: Input Voltage up to 300V. For any higher Input Voltage large than 300V, please 
add the PT (power transformer), and Change PT RATIO setup.  

 
Notice: Please check the L‐N connection of PM‐311x‐xxxC series or it will cause the damage. Please refer 
the following diagram. 

 

 
 
3.3. Current Input  
 

1. The external CT’s are fragile, please handle with care.  

2. The current input of PM-311x series is in mA range. Only the ex-factory attached CT’s can be used. 

The other CT’s, for example, from panel will damage the instrument due to its large current (around 
5A) 

3. When more than one smart meters (PM-311x series) are installed, please do not disconnect the CT 

with its original meter and mix us e with each other. Since each set of smart meter (PM- 311x series) 
and its attached split type clip -on CT are calibrated set by set. The mix use may cause wrong 
measurements. 

4. To install CT’s correctly, please ensure the CT lines sequences is right before clip the CT’s onto the 

power cable of the monitoring equipment. (De tail will be found in next section) 

5. When measuring the current, the secondary circuit of a CT should never be opened when a load is 

passing through its primary. Make sure you always open the CT clip to detach the CT before removing 
the terminal lines. Otherwise, it will cause severe injury. 

6. Plea se handle with extra care, especially when the operation space of CT’s is limited. 
7. The current direction must follow K-L marked on CT’s. 
8. Please select the right size CT’s for different size of monitoring equipment cables: 

    Power cable diameter 

<Φ

10 use 60 A CT

,Φ

10

~Φ

16 use 100A CT

,Φ

16

~Φ

24 use 200A CT 

9. The maximum current value cannot exceed the CT rating. 

 

Summary of Contents for PM-3112-160-MTCP

Page 1: ...ages range 10 300 VAC which allow s worldwide compatibility And with 2 channels relay output it can be linked with sirens or lightings for alarm messages It also supports Modbus R TU Modbus TCP or CAN bus protocols for easy integration 2 1 Caution Warning The meter contains hazardous voltages and should never be disassembled Failing to follow this practice will result in serious injury or death An...

Page 2: ...ther than electrical power monitoring The supplied meter is not a user serviceable product 3 Installation Please use the soft dry clothes to clean the instrument Please do not use any chemical or detergent or volatile solvents to clean the instrument in order to avoid any possibility of the cover damage 3 1 Dimension 127mm length 33mm wide 105mm high Products come with external split type clip on ...

Page 3: ...isconnect the CT with its original meter and mix us e with each other Since each set of smart meter PM 311x series and its attached split type clip on CT are calibrated set by set The mix use may cause wrong measurements 4 To install CT s correctly please ensure the CT lines sequences is right before clip the CT s onto the power cable of the monitoring equipment De tail will be found in next secti...

Page 4: ...PM 3112 160 MTCP 2 Loops single phase Smart Power Meter QuickStart Feb 2019 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 4 3 4 Connection ...

Page 5: ...12 160 MTCP 2 Loops single phase Smart Power Meter QuickStart Feb 2019 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 5 3 5 CT s installation steps 3 6 Wiring ...

Page 6: ...tput LED Indicator Relay Output LED Indicator The PM 311x as 4 LED to indicate the unit power status communication and power data calculation RUN Green light up after communication ready LED will flash when the unit is processing communication PWR Red Power on LED always on DO0 Green LED DO0 will light up when DO0 is ON DO1 Green LED DO1 will light up when DO1 is ON 5 Communication ...

Page 7: ...PM 3112 160 MTCP 2 Loops single phase Smart Power Meter QuickStart Feb 2019 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 7 ...

Page 8: ...PM 3112 160 MTCP 2 Loops single phase Smart Power Meter QuickStart Feb 2019 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 8 ...

Reviews: